Short Description: The ABB XT1N160 TMD80/800 FFC 3P is a three-pole molded case circuit breaker with thermal-magnetic release, offering adjustable over-current settings and robust short-circuit protection up to 65kA.
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 50 kA (230 V AC) 50 kA (240 V AC) 50 kA (380 V AC) 36 kA (415 V AC) 36 kA (440 V AC) 18 kA (500 V AC) 15 kA (525 V AC) 11 kA (690 V AC) 5 kA (250 V DC) 2 Poles in Series 36 kA (500 V DC) 3 Poles in Series 36 kA
(220 V AC) 65 kA (230 V AC) 65 kA (240 V AC) 65 kA (380 V AC) 36 kA (415 V AC) 36 kA (440 V AC) 36 kA (500 V AC) 30 kA (525 V AC) 22 kA (690 V AC) 6 kA (250 V DC) 2 Poles in Series 36 kA (500 V DC) 3 Poles in Series 36 kA
Rated Uninterrupted Current (Iu)
160 A
Release
TMD
Release Type
TM
Remarks
ATLAS
Short-Circuit Performance Level
N
Product Highlights
1. Advanced Protection Mechanism
The XT1N160 TMD80/800 FFC 3P features a thermal-magnetic release mechanism, providing both thermal and magnetic protection against overloads and short circuits. This ensures reliable and efficient electrical protection.
2. Adjustable Over-Current Settings
With adjustable over-current settings ranging from 56A to 80A, the circuit breaker can be customized to meet specific application requirements, enhancing its versatility and effectiveness.
3. High Breaking Capacity
The XT1N160 TMD80/800 FFC 3P boasts a high breaking capacity of up to 65kA at 240V AC, making it suitable for demanding electrical installations where high short-circuit currents are expected.
4. Robust Design and Durability
Constructed with high-quality materials, the circuit breaker offers excellent electrical durability with up to 8000 operations under load and mechanical durability with up to 25,000 operations at no load, ensuring long-lasting performance.
5. Compliance with International Standards
The XT1N160 TMD80/800 FFC 3P is compliant with IEC 60947-1 and IEC 60947-2 standards, ensuring it meets the highest international safety and performance requirements. Additionally, it adheres to the EU's Low Voltage Directive (LVD) and Electromagnetic Compatibility Directive (EMC).
Standards
IEC60947-2 GB/T 14028.2
Sub-type
XT1
Terminal Connection Type
Front for Copper Cables
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Manufacturer ID
2TFH100085R1001
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.
Need Help Checking This Part?
Ask about specifications, condition or a suitable alternative.