ABB XT4N 160 Ekip M-LIU R63 FF 3P: High-performance, 63A, 3-pole circuit breaker with front terminals for TMax XT systems, ensuring reliable and efficient electrical protection.
Product ModelXT4N160 EKIP M-LIU R63 FF 3P
Material Number2TFH100370R1001
Product ID92792
Stock on Request
Last updated: 8/29/2026
Key Features
1
Feature1. High-Performance Protection The ABB XT4N 160 Ekip M-LIU R63 FF 3P circuit breaker is designed to provide robust protection against electrical faults, ensuring the safety and reliability of your electrical system.
2
Feature2. Compatibility with TMax XT Systems Specifically engineered for TMax XT systems, this circuit breaker seamlessly integrates into your existing infrastructure, enhancing overall system efficiency and performance.
3
Feature3. Front Terminal Design Equipped with front terminals, this circuit breaker offers easy and convenient installation and maintenance, reducing downtime and increasing operational efficiency.
4
Feature4. Electrical Durability Built to withstand 120 cycles per hour and a total of 8000 cycles, this circuit breaker ensures long-lasting performance and reliability in demanding electrical environments.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Environmental Information
9AKK108467A6707
Product Net Width
105.0 mm
Product Net Height
160.0 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
2.5 kg
Product Main Type
SACE Tmax XT
5
Feature5. Compliance with International Standards Meets IEC standards, ensuring compliance with international safety and performance regulations, providing peace of mind for users in various global applications.
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
Current Type
AC
Electrical Durability
8000 cycle 120 cycles per hour
Mechanical Durability
25000 cycle 240 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 1.4 W
Rated Current (In)
63 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 65 kA (230 V AC) 65 kA (240 V AC) 65 kA (380 V AC) 36 kA (415 V AC) 36 kA (440 V AC) 36 kA (500 V AC) 30 kA (525 V AC) 20 kA (690 V AC) 10 kA
(220 V AC) 65 kA (230 V AC) 65 kA (240 V AC) 65 kA (380 V AC) 36 kA (415 V AC) 36 kA (440 V AC) 36 kA (500 V AC) 30 kA (525 V AC) 20 kA (690 V AC) 10 kA
Rated Uninterrupted Current (Iu)
160 A
Release
Ekip M-LIU
Release Type
EL
Remarks
ATLAS
Short-Circuit Performance Level
N
Standards
IEC60947-2 GB/T 14028.2
Sub-type
XT4
Terminal Connection Type
Front
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)