The SACE Tmax XT2H 160 Ekip Touch Measuring LSIG 4P Fixed Circuit Breaker provides advanced protection and measurement capabilities for electrical distribution systems. It features high breaking capacity, robust design, and efficient monitoring.
Specifications for XT2H 160 Ekip Touch Measuring LSIG In=40A 4p F F
Parameter
Value
Environmental Information
9AKK108467A6707
Product Net Width
120.0 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.6 kg
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
Current Type
AC
Electrical Durability
8000 cycle 120 cycles per hour
Mechanical Durability
25000 cycle 240 cycles per hour
Number of Poles
4P
Rated Current (In)
40 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA (230 V AC) 100 kA (240 V AC) 100 kA (380 V AC) 70 kA (415 V AC) 70 kA (440 V AC) 65 kA (500 V AC) 50 kA (525 V AC) 30 kA (690 V AC) 15 kA
(220 V AC) 100 kA (230 V AC) 100 kA (240 V AC) 100 kA (380 V AC) 70 kA (415 V AC) 70 kA (440 V AC) 65 kA (500 V AC) 50 kA (525 V AC) 30 kA (690 V AC) 15 kA
Rated Uninterrupted Current (Iu)
160 A
Release
Ekip Touch Measuring LSIG
Release Type
EL
Product Highlights
1. Advanced Protection Features
The SACE Tmax XT2H 160 Ekip Touch Measuring LSIG 4P Fixed Circuit Breaker is equipped with advanced protection features, including Ekip Touch technology, which enhances safety and reliability in electrical distribution systems.
2. High Breaking Capacity
With a high breaking capacity, this circuit breaker can handle short-circuit currents effectively, ensuring the safety of your electrical infrastructure.
3. Efficient Measurement Capabilities
The Ekip Touch Measuring LSIG module provides precise measurement and monitoring capabilities, allowing you to track and manage electrical currents efficiently.
4. Robust Design and Durability
Designed with a robust and durable structure, the SACE Tmax XT2H 160 can withstand harsh environmental conditions and heavy usage, ensuring long-term reliability.
5. Easy Installation and Maintenance
The fixed design and front terminals make installation and maintenance straightforward, reducing downtime and increasing operational efficiency.
Short-Circuit Performance Level
H
Standards
IEC60947-2 GB/T 14028.2
Sub-type
XT2
Terminal Connection Type
Front
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Manufacturer ID
2TFN000218A1001
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.
Need Help Checking This Part?
Ask about specifications, condition or a suitable alternative.