ABB XT1N 160 TMD 125/1250 3P FF: A high-performance, three-pole circuit breaker with thermomagnetic release and front terminals, ideal for transformer, generator, and installation protection.
Specifications for XT1N 160 TMD125/1250 F F 3P-ABB Robotics
Parameter
Value
Environmental Information
9AKK108467A6707
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.1 kg
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
Current Type
AC/DC
Electrical Durability
8000 cycle 120 cycles per hour
Mechanical Durability
25000 cycle 240 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 10.7 W
Rated Current (In)
125 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 50 kA (230 V AC) 50 kA (240 V AC) 50 kA (380 V AC) 36 kA (415 V AC) 36 kA (440 V AC) 18 kA (500 V AC) 15 kA (525 V AC) 11 kA (690 V AC) 5 kA (250 V DC) 2 Poles in Series 36 kA (500 V DC) 3 Poles in Series 36 kA
(220 V AC) 65 kA (230 V AC) 65 kA (240 V AC) 65 kA (380 V AC) 36 kA (415 V AC) 36 kA (440 V AC) 36 kA (500 V AC) 30 kA (525 V AC) 22 kA (690 V AC) 6 kA (250 V DC) 2 Poles in Series 36 kA (500 V DC) 3 Poles in Series 36 kA
Rated Uninterrupted Current (Iu)
Product Highlights
1. Reliable Power Distribution
The ABB XT1N 160 TMD 125/1250 3P FF ensures reliable power distribution with its robust design and high short-circuit breaking capacity, making it perfect for critical applications like transformer and generator protection.
2. Thermomagnetic Release
Equipped with a thermomagnetic release mechanism, this circuit breaker provides fast and efficient tripping in case of an overload or fault, ensuring safety and minimizing downtime.
3. Front Terminal Connection
The front terminal connection of the XT1N 160 TMD 125/1250 3P FF simplifies installation and maintenance, reducing the time and effort required for connecting and disconnecting the circuit breaker.
4. High Short-Circuit Breaking Capacity
With a short-circuit breaking capacity of up to 65 kA at 220-240 V AC and 36 kA at 380-440 V AC, this circuit breaker can handle high fault currents, ensuring reliable operation under demanding conditions.
5. Compliance with International Standards
The XT1N 160 TMD 125/1250 3P FF meets IEC standards, ensuring compliance with international safety and performance regulations, making it a trusted choice for global applications.
6. Environmental Sustainability
Designed with environmental sustainability in mind, this circuit breaker adheres to EU Directive 2011/65/EU and Amendment 2015/863, reducing the environmental impact of electronic waste and promoting recyclability.
160 A
Release
TMD
Release Type
TM
Short-Circuit Performance Level
N
Standards
IEC60947-2 GB/T 14028.2
Sub-type
XT1
Terminal Connection Type
Front
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Manufacturer ID
2TFC000012R1001