Short Description: The ABB XT1S 160 TMD 160-1600 4P F F InN=100% is a fixed, four-pole circuit breaker with front terminals and thermomagnetic release, ideal for applications requiring high reliability and efficient power distribution.
Specifications for XT1S160 TMD160/1600 FEF 4P N =100%
Parameter
Value
Environmental Information
9AKK108467A6707
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
Current Type
AC/DC
Electrical Durability
8000 cycle 120 cycles per hour
Mechanical Durability
25000 cycle 240 cycles per hour
Number of Poles
4P
Power Loss
at Rated Operating Conditions per Pole 15 W
Rated Current (In)
160 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 63.75 kA (230 V AC) 63.75 kA (240 V AC) 63.75 kA (380 V AC) 50 kA (415 V AC) 37.5 kA (440 V AC) 25 kA (500 V AC) 18 kA (525 V AC) 17.5 kA (690 V AC) 5 kA (250 V DC) 2 Poles in Series 50 kA (500 V DC) 3 Poles in Series 50 kA
(220 V AC) 85 kA (230 V AC) 85 kA (240 V AC) 85 kA (380 V AC) 50 kA (415 V AC) 50 kA (440 V AC) 50 kA (500 V AC) 36 kA (525 V AC) 35 kA (690 V AC) 8 kA (250 V DC) 2 Poles in Series 50 kA (500 V DC) 3 Poles in Series 50 kA
Rated Uninterrupted Current (Iu)
160 A
Release
TMD
Release Type
TM
Short-Circuit Performance Level
S
Standards
IEC60947-2 GB/T 14028.2
Product Highlights
1. High Reliability and Efficiency
The XT1S 160 TMD 160-1600 4P F F InN=100% is designed to provide reliable and efficient power distribution, ensuring minimal downtime and maximum operational performance.
2. Thermomagnetic Release
Equipped with a thermomagnetic release (TMD), this circuit breaker ensures safe and efficient operation under various electrical conditions, including short circuits and overloads.
3. Four-Pole Configuration
The four-pole design allows for fully rated neutral, making it suitable for applications requiring balanced and reliable power distribution.
4. Front Terminal Connection
The front terminal connection type (F) simplifies installation and maintenance, reducing the need for complex wiring and ensuring quick access to the circuit breaker.
5. Compliance with IEC Standards
The XT1S 160 TMD 160-1600 4P F F InN=100% complies with IEC standards, ensuring it meets the highest safety and performance requirements for electrical installations.
Sub-type
XT1
Terminal Connection Type
Front Extended
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Manufacturer ID
2TFH100146R1001
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.
Need Help Checking This Part?
Ask about specifications, condition or a suitable alternative.