Short Description: ABB XT2L 160 Ekip C Dip LSI R100 FF 3P - High-reliability, three-pole moulded case circuit breaker for AC applications, ensuring robust short-circuit breaking capacities and compliance with IEC standards.
Specifications for XT2L 160 Ekip C Dip LSI R100 F F 3P
Parameter
Value
Environmental Information
1SDL000190R0001
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.2 kg
Product Name
Moulded Case Circuit Breaker
Product Type
CB
Version
F
Current Type
AC
Electrical Durability
8000 cycle 120 cycles per hour
Mechanical Durability
25000 cycle 240 cycles per hour
Number of Poles
3P
Power Loss
at Rated Operating Conditions per Pole 4.20 W
Rated Current (In)
100 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
690 V AC 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 150 kA (230 V AC) 150 kA (240 V AC) 150 kA (380 V AC) 120 kA (415 V AC) 120 kA (440 V AC) 100 kA (500 V AC) 60 kA (525 V AC) 36 kA (690 V AC) 15 kA (250 V DC) 2 Poles in Series 85 kA (500 V DC) 3 Poles in Series 85 kA
(220 V AC) 150 kA (230 V AC) 150 kA (240 V AC) 150 kA (380 V AC) 120 kA (415 V AC) 120 kA (440 V AC) 100 kA (500 V AC) 60 kA (525 V AC) 36 kA (690 V AC) 18 kA (250 V DC) 2 Poles in Series 85 kA (500 V DC) 3 Poles in Series 85 kA
Rated Uninterrupted Current (Iu)
160 A
Release
Ekip C Dip LSI
Product Highlights
1. High Reliability and Efficiency
The ABB XT2L 160 Ekip C Dip LSI R100 FF 3P is designed to provide high reliability and efficiency in electrical distribution systems. Its solid-state release mechanism ensures consistent performance under various operating conditions.
2. Robust Short-Circuit Breaking Capacities
Equipped with robust short-circuit breaking capacities, this circuit breaker can handle high fault currents, ensuring the safety of your electrical system and minimizing downtime.
3. Compliance with IEC Standards
The XT2L series adheres to IEC standards, ensuring that the product meets the highest international safety and performance criteria. This guarantees compatibility with a wide range of electrical systems.
4. Three-Pole Configuration
The three-pole design allows for balanced distribution of electrical loads, reducing the risk of overloading and improving overall system efficiency. This configuration is ideal for applications requiring symmetrical load distribution.
5. Front Terminal Connection
Featuring front terminal connections, the XT2L 160 Ekip C Dip LSI R100 FF 3P offers easy installation and maintenance. The front terminals provide direct access to the circuit breaker’s connections, simplifying the process of connecting and disconnecting electrical circuits.
Release Type
EL
Short-Circuit Performance Level
L
Standards
IEC 60947-2 GB/T 14028.2
Sub-type
XT2
Terminal Connection Type
Fixed Circuit-Breakers
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Manufacturer ID
2TFC000946R1001
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.
Need Help Checking This Part?
Ask about specifications, condition or a suitable alternative.