ABB NF33/11-13: 8-pole contactor relay for 100-250V, 50/60Hz AC and DC. Built-in surge protection, flexible control voltage range, and a wide range of accessories.
Product ModelNF33/11-13
Material Number1SBH137001R1339
Product ID88215
Stock on Request
Last updated: 8/29/2026
Key Features
1
1. Versatile Control Voltage RangeThe NF33/11-13 can manage control voltages between 24V and 500V, making it suitable for various applications worldwide without the need for coil changes.
2
2. Built-in Surge ProtectionThis contactor relay features built-in surge protection, eliminating the need for additional surge suppressors, ensuring reliable operation in harsh electrical environments.
3
3. Flexible Connection OptionsThe NF33/11-13 offers flexible connection options including insulated ferrules and rigid stranded wires, making it easy to integrate into different electrical systems.
4
4. High Performance and DurabilityWith a rated operational current of up to 140A for 0.1 seconds and 100A for 1 second, this contactor relay is designed to handle high electrical demands while maintaining durability.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Product Net Width
45 mm
Product Net Depth / Length
110.5 mm
Product Net Height
86 mm
Product Net Weight
0.32 kg
Number of Auxiliary Contacts NO
4
Number of Auxiliary Contacts NC
4
5
5. Compliance with International StandardsThe NF33/11-13 complies with international standards such as IEC 60947-5-1, UL 508, and CSA C22.2 N14, ensuring it meets the requirements for safe and reliable operation in various environments.
Standards
IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13
(500 V) 2 A (690 V) 2 A (24 / 127 V) 6 A (220 / 240 V) 4 A (400 / 440 V) 3 A
Rated Short-time Withstand Current Low Voltage (Icw)
for 0.1 s 140 A for 1 s 100 A
Maximum Electrical Switching Frequency
(AC-15) 1200 cycles per hour (DC-13) 900 cycles per hour
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W (48 V) 2.8 A / 134 W (72 V) 1 A / 72 W (110 V) 0.55 A / 60 W (125 V) 0.55 A / 69 W (220 V) 0.27 A / 60 W (250 V) 0.27 A / 68 W (400 V) 0.15 A / 60 W (500 V) 0.13 A / 65 W (600 V) 0.1 A / 60 W
Rated Insulation Voltage (Ui)
acc. to IEC 60947-5-1 690 V acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Maximum Mechanical Switching Frequency
6000 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 100 ... 250 V 60 Hz 100 ... 250 V DC Operation 100 ... 250 V
Operate Time
Between Coil De-energization and NC Contact Closing 13 ... 98 ms Between Coil De-energization and NO Contact Opening 11 ... 95 ms Between Coil Energization and NC Contact Opening 38 ... 90 ms Between Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Auxiliary Circuit 11 in·lb Control Circuit 11 in·lb
Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °C Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: B1 25 g Closed, Shock Direction: B2 15 g Open, Shock Direction: B1 5 g Shock Direction: A 30 g Shock Direction: B2 15 g Shock Direction: C1 25 g
Resistance to Vibrations
4g Closed Position & 2g Open position 5 ... 300 Hz
Object Classification Code
K
ETIM 7
EC000196 - Contactor relay
ETIM 8
EC000196 - Contactor relay
ETIM 9
EC000196 - Contactor relay
eClass
V11.0 : 27371001
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4763 >> Power contactor, DC switching
Manufacturer ID
1SBH137001R1339
ABB NF33/11-13 100-250V 50/60Hz DC Contactor Relay - Flexible and Reliable | INDSLT