The ABB XT1N 125 TMF 30-500 3P FF UL/CSA is a reliable, three-pole moulded case circuit breaker certified to UL and CSA standards. It features a thermal-magnetic trip and is suitable for various distribution levels.
Specifications for XT1N 125 TMF 30-500 3p F F UL/CSA
Parameter
Value
Environmental Information
9AKK108467A6707
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.1 kg
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
1SDH001295R0008
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour 8000 cycle
Mechanical Durability
240 cycles per hour 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 15 ms CB with UVR 15 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 1.8 W
Rated Current (In)
30 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
500 A
Rated Operational Voltage
600Y/347 V AC 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
Product Highlights
1. High Performance and Reliability
The ABB XT1N 125 TMF 30-500 3P FF UL/CSA is designed to provide consistent and reliable performance in high-demand applications. Its robust construction ensures long-lasting operation.
2. Certified to UL and CSA Standards
This circuit breaker meets the stringent standards set by UL (Underwriters Laboratories) and CSA (Canadian Standards Association), ensuring it meets safety and performance requirements.
3. Thermal-Magnetic Trip
Equipped with a thermal-magnetic trip mechanism, the XT1N 125 TMF offers both thermal and magnetic protection, providing comprehensive safety against overcurrent conditions.
4. Versatile Application
Ideal for various distribution levels, from main low voltage switchboards to subswitchboards, the XT1N 125 TMF is a versatile solution for diverse electrical needs.
5. Durable Design
Constructed with high-quality materials, the XT1N 125 TMF is designed to withstand harsh electrical environments, ensuring it remains functional even under extreme conditions.
600Y/347 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
30 A
Short-Circuit Performance Level
N
Standards
UL489
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 50 kA (480 V AC) 25 kA (600Y / 347 V AC) 18 kA (250 V DC) 2 Poles in Series 35 kA (500 V DC) 4 Poles in Series Kind 35 kA
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA074637R1
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.
Need Help Checking This Part?
Ask about specifications, condition or a suitable alternative.