Short Description: ABB XT4N 250 TMF 150-1500 3P F F UL/CSA - Advanced thermal-magnetic protection, UL/CSA certified, 3 poles, 150A rated current, 1500A short-circuit pickup current.
Product ModelXT4N 250 TMF 150-1500 3p F F UL/CSA
Material Number1SDA080108R1
Product ID87361
Stock on Request
Last updated: 8/29/2026
Key Features
1
1. Advanced Thermal-Magnetic ProtectionThe XT4N 250 TMF features advanced thermal-magnetic protection, ensuring reliable operation under various load conditions.
2
2. UL/CSA CertificationCertified to both UL and CSA standards, this circuit breaker meets stringent safety requirements, providing peace of mind for your electrical installations.
3
3. High Current RatingWith a rated current of 150A and a short-circuit pickup current of 1500A, the XT4N 250 TMF is designed to handle demanding electrical loads.
4
4. Compact DesignThe compact dimensions (H160mm x W105mm x D82.5mm) make it ideal for a variety of applications, from small equipment to larger installations.
5
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Environmental Information
9AKK108467A6707
Product Net Width
105 mm
Product Net Height
160 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
2.5 kg
Circuit Breaker Type to be Associated
Power Distribution
5. Reliable PerformanceBuilt with high-quality components, the XT4N 250 TMF ensures reliable performance over a wide range of operating conditions, including 8000 cycles of electrical durability and 25,000 mechanical operations.
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
1SDH002230A1003
Connecting Capacity Main Circuit
Busbar 85..200 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour 8000 cycle
Mechanical Durability
240 cycles per hour 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 15 ms CB with UVR 15 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 7.8 W
Rated Current (In)
150 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
1500 A
Rated Operational Voltage
600 V AC 600 V DC
Rated Uninterrupted Current (Iu)
250 A
Rated Voltage (Ur)
600 V
Recommended Screw Driver
Main Circuit M8
Release
TMF
Release Type
TM
Setting Range
150 A
Short-Circuit Performance Level
N
Standards
UL489
Sub-type
XT4
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
8 N·m
Interrupting Rating acc. to UL489
(240 V AC) 65 kA (480 V AC) 25 kA (600 V AC) 18 kA (250 V DC) 2 Poles in Series 35 kA (600 V DC) 3 Poles in Series 35 kA
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA080108R1
ABB XT4N 250 TMF 150-1500 3P F F UL/CSA Molded Case Circuit Breaker | INDSLT