ABB XT4N 250 TMF 80-800 2p F F UL/CSA: Reliable, high-performance molded case circuit breaker for power distribution with robust electrical and mechanical durability.
Product ModelXT4N 250 TMF 80-800 2p F F UL/CSA
Material Number1SDA080134R1
Product ID86877
Stock on Request
Last updated: 8/29/2026
Key Features
1
1. Robust Electrical DurabilityThe ABB XT4N 250 TMF 80-800 2p F F UL/CSA is engineered to withstand 120 cycles per hour and up to 8000 cycles, ensuring reliable operation in demanding electrical environments.
2
2. Mechanical DurabilityWith a mechanical durability of 240 cycles per hour and up to 25,000 cycles, this circuit breaker is designed to handle frequent operations with minimal wear and tear.
3
3. High Current RatingRated at 250 A, this circuit breaker is suitable for applications requiring high current handling, making it ideal for power distribution systems.
4
4. Compliance with StandardsThe XT4N 250 TMF 80-800 2p F F UL/CSA meets UL standards, ensuring compliance with safety regulations and providing peace of mind for users.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Environmental Information
9AKK108467A6707
Product Net Width
105 mm
Product Net Height
160 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
2.05 kg
Circuit Breaker Type to be Associated
Power Distribution
5
5. Versatile ApplicationDesigned for both AC and DC applications, this circuit breaker is versatile and can be used in a variety of settings, including transformer and generator installations.
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
Current Type
AC/DC
Electrical Durability
120 cycles per hour 8000 cycle
Mechanical Durability
240 cycles per hour 25000 cycle
Number of Poles
2P
Opening Time
CB with SOR 15 ms CB with UVR 15 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 5.5 W
Rated Current (In)
80 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
800 A
Rated Operational Voltage
600 V AC 500 V DC
Rated Uninterrupted Current (Iu)
250 A
Rated Voltage (Ur)
600 V
Release
TMF
Release Type
TM
Setting Range
80 A
Short-Circuit Performance Level
N
Standards
UL489
Sub-type
XT4
Terminal Connection Type
Front
Interrupting Rating acc. to UL489
(240 V AC) 65 kA (480 V AC) 25 kA (600 V AC) 18 kA (250 V DC) 2 Poles in Series 35 kA (600 V DC) 3 Poles in Series 35 kA
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA080134R1