The ABB XT1B 160 TMD 40-450 4p F F is a high-performance, four-pole molded case circuit breaker with a thermomagnetic release (TMD) and a rated current of 40 A. It is designed for reliable power distribution in various electrical systems.
Rated Instantaneous Short-Circuit Current Setting (Ii)
450 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
Product Highlights
1. High-Performance Design
The ABB XT1B 160 TMD 40-450 4p F F is engineered with a robust design to ensure reliable performance in demanding electrical environments. Its thermomagnetic release (TMD) provides quick and efficient tripping in case of overcurrent conditions.
2. Wide Voltage and Current Range
This circuit breaker supports a wide range of voltages, including 690 V AC and 500 V DC, and a rated current of 40 A. It is suitable for various applications requiring high voltage and current handling.
3. Enhanced Safety Features
The XT1B 160 TMD 40-450 4p F F is designed with safety in mind. It features a thermomagnetic release mechanism that ensures safe and reliable operation, reducing the risk of electrical accidents.
4. Efficient Short-Circuit Performance
With a rated instantaneous short-circuit current setting of 450 A, this circuit breaker is capable of handling high short-circuit currents efficiently. It provides reliable protection against electrical faults, ensuring the integrity of your electrical system.
5. Compliance with International Standards
The ABB XT1B 160 TMD 40-450 4p F F complies with international standards such as IEC, ensuring that it meets the highest standards of quality and performance. This compliance provides peace of mind for users who require products that meet global safety and performance criteria.
690 V AC 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 25 kA (230 V AC) 25 kA (240 V AC) 25 kA (380 V AC) 18 kA (415 V AC) 18 kA (440 V AC) 11.25 kA (500 V AC) 8 kA (525 V AC) 6 kA (690 V AC) 3 kA (250 V DC) 2 Poles in Series 18 kA (500 V DC) 3 Poles in Series 18 kA
(220 V AC) 25 kA (230 V AC) 25 kA (240 V AC) 25 kA (380 V AC) 18 kA (415 V AC) 18 kA (440 V AC) 15 kA (500 V AC) 8 kA (525 V AC) 6 kA (690 V AC) 3 kA (250 V DC) 2 Poles in Series 18 kA (500 V DC) 3 Poles in Series 18 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
28...40 A
Short-Circuit Performance Level
B
Standards
IEC60947-2
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA066814R1
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.
Need Help Checking This Part?