High-performance molded case circuit breaker with thermomagnetic trip unit, front terminals, and UL/CSA certification for 600V, 60A applications.
Product ModelXT2V 125 TMF 60-600 4p F F UL/CSA
Material Number1SDA074866R1
Product ID86679
Stock on Request
Last updated: 8/29/2026
Key Features
1
1. Reliable PerformanceThe ABB XT2V 125 TMF 60-600 4p F F UL/CSA is engineered to provide reliable performance in demanding electrical environments, ensuring consistent operation and minimal downtime.
2
2. Compliance with StandardsThis circuit breaker meets the stringent standards of UL and CSA, ensuring it is safe and compliant for use in a variety of applications.
3
3. Efficient DesignWith its thermomagnetic trip unit, this circuit breaker efficiently detects and responds to overcurrent conditions, providing quick and effective protection against electrical faults.
4
4. Versatile ApplicationDesigned for 4-pole configurations, this circuit breaker is versatile and can be used in a range of applications, from industrial settings to commercial environments.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Environmental Information
9AKK108467A6707
Product Net Width
120 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.45 kg
Circuit Breaker Type to be Associated
Power Distribution
5
5. Front Terminal AccessibilityThe front terminals of the ABB XT2V 125 TMF 60-600 4p F F UL/CSA make it easy to connect and disconnect wires, enhancing user convenience and reducing installation time.
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
1SDH002230A1002
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour 8000 cycle
Mechanical Durability
240 cycles per hour 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 15 ms CB with UVR 15 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 4.4 W
Rated Current (In)
60 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
600 A
Rated Operational Voltage
600 V AC 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
60 A
Short-Circuit Performance Level
V
Standards
UL489
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 200 kA (480 V AC) 150 kA (600 V AC) 42 kA (250 V DC) 2 Poles in Series 85 kA (500 V DC) 3 Poles in Series 85 kA
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA074866R1
ABB XT2V 125 TMF 60-600 4p F F UL/CSA Molded Case Circuit Breaker | INDPRT