The ABB XT2H 160 MF 12.5 A 3P FF circuit breaker is a high-performance, three-pole molded case circuit breaker with a rated current of 12.5 A and a short-circuit breaking capacity of 100 kA. It features magnetic release and front terminals, making it suitable for various industrial applications.
Rated Instantaneous Short-Circuit Current Setting (Ii)
175 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
Product Highlights
1. High Performance and Reliability
The XT2H 160 MF 12.5 A 3P FF circuit breaker is designed to provide reliable operation in industrial settings, ensuring minimal downtime and maximum efficiency.
2. Magnetic Release
Equipped with a magnetic release mechanism, this circuit breaker ensures safe and efficient operation, particularly in applications where manual intervention may be challenging.
3. Front Terminal Connection
The front terminal connection type allows for easy installation and maintenance, reducing the time and effort required for setup and troubleshooting.
4. Short-Circuit Breaking Capacity
With a short-circuit breaking capacity of 100 kA, this circuit breaker can handle high short-circuit currents, making it suitable for a wide range of industrial applications.
5. Compliance with International Standards
The XT2H 160 MF 12.5 A 3P FF circuit breaker complies with IEC standards, ensuring that it meets the highest safety and performance requirements for industrial use.
690 V AC 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA (230 V AC) 100 kA (240 V AC) 100 kA (380 V AC) 70 kA (415 V AC) 70 kA (440 V AC) 65 kA (500 V AC) 50 kA (525 V AC) 30 kA (690 V AC) 15 kA (250 V DC) 2 Poles in Series 70 kA (500 V DC) 3 Poles in Series 70 kA
(220 V AC) 100 kA (230 V AC) 100 kA (240 V AC) 100 kA (380 V AC) 70 kA (415 V AC) 70 kA (440 V AC) 65 kA (500 V AC) 50 kA (525 V AC) 30 kA (690 V AC) 15 kA (250 V DC) 2 Poles in Series 70 kA (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
MF
Release Type
M
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4932 >> 3 Pole Non-Interchangeable Trip Electronic Circuit Breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA067774R1
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.
Need Help Checking This Part?
Ask about specifications, condition or a suitable alternative.