ABB NFZB31E-22: A contactor relay for railway rolling stock, compliant with latest standards, suitable for passenger or driver cabins. Ensures safe and efficient operations.
Product ModelNFZB31E-22
Material Number1SBH136061R2231
Product ID86360
Stock on Request
Last updated: 8/29/2026
Key Features
1
1. Compliance with Railway StandardsThe ABB NFZB31E-22 is designed to meet the latest railway rolling stock standards, ensuring it is safe and reliable for use in passenger or driver cabins.
2
2. Efficient OperationsThis contactor relay is engineered to provide efficient operations, minimizing downtime and maximizing performance in demanding environments.
3
3. Versatile InstallationThe NFZB31E-22 can be installed in various locations within the railway system, including passenger or driver cabins, making it a versatile solution for different applications.
4
4. High ReliabilityBuilt with high-quality components, the ABB NFZB31E-22 offers exceptional reliability, reducing the risk of failures and ensuring continuous operation.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Product Net Width
45 mm
Product Net Depth / Length
77 mm
Product Net Height
86 mm
Product Net Weight
0.31 kg
Number of Auxiliary Contacts NO
3
Number of Auxiliary Contacts NC
1
5
5. Customizable OptionsAvailable with auxiliary contacts (1 NC + 3 NO), the NFZB31E-22 provides customizable options to meet specific operational requirements, enhancing its flexibility and usability.
Standards
IEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-5-1, CSA C22.2 No. 60947-5-1, IEC 60077-1 (applicable parts), IEC 60077-2 (applicable parts), EN 50155 (applicable parts), TR CU 001/2011, IEC 61373, For compliance confirmation on applicable parts based on your application and combination, please consult your ABB sales representatives.
Rated Operational Voltage
Auxiliary Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 Hz Control Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-5-1, Π= 40 °C 16 A
Rated Operational Current AC-15 (Ie)
(500 V) 2 A (690 V) 2 A (24 / 127 V) 6 A (220 / 240 V) 4 A (400 / 440 V) 3 A
Rated Short-time Withstand Current Low Voltage (Icw)
for 0.1 s 140 A for 1 s 100 A
Maximum Electrical Switching Frequency
(AC-15) 1200 cycles per hour (DC-13) 900 cycles per hour
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W (48 V) 2.8 A / 134 W (72 V) 1 A / 72 W (110 V) 0.55 A / 60 W (125 V) 0.55 A / 69 W (220 V) 0.27 A / 60 W (250 V) 0.27 A / 68 W (400 V) 0.15 A / 60 W (500 V) 0.13 A / 65 W (600 V) 0.1 A / 60 W
Rated Insulation Voltage (Ui)
acc. to IEC 60947-5-1 690 V acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Maximum Mechanical Switching Frequency
6000 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 48 ... 130 V 60 Hz 48 ... 130 V DC Operation 48 ... 130 V
Operate Time
Between Coil De-energization and NC Contact Closing 13 ... 98 ms Between Coil De-energization and NO Contact Opening 11 ... 95 ms Between Coil Energization and NC Contact Opening 38 ... 90 ms Between Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN Rail