High-performance, four-pole molded case circuit breaker with thermomagnetic release and front terminals, meeting UL/CSA standards for reliability and safety.
Product ModelXT4N 250 TMF 50-500 4p F F UL/CSA
Material Number1SDA075175R1
Product ID86214
Stock on Request
Last updated: 8/29/2026
Key Features
1
1. Reliability and SafetyThe ABB XT4N 250 TMF 50-500 4p F F UL/CSA is designed to meet stringent UL/CSA standards, ensuring high reliability and safety in power distribution applications.
2
2. Thermomagnetic ReleaseEquipped with a thermomagnetic release mechanism, this circuit breaker provides efficient and reliable tripping in case of overcurrent conditions.
3
3. Front Terminal ConnectionThe front terminal connection makes installation and maintenance easier, reducing downtime and increasing operational efficiency.
4
4. High PerformanceWith a rated current of 250 A and a short-circuit breaking capacity of up to 35 kA, this circuit breaker is suitable for demanding power distribution applications.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Environmental Information
9AKK108467A6707
Product Net Width
140 mm
Product Net Height
160 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
3.5 kg
Circuit Breaker Type to be Associated
Power Distribution
5
5. Mechanical DurabilityDesigned to withstand 240 cycles per hour and 25,000 cycles in total, this circuit breaker ensures long-lasting performance in harsh operating conditions.
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
1SDH001295R0677
Connecting Capacity Main Circuit
Busbar 85..200 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour 8000 cycle
Mechanical Durability
240 cycles per hour 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 15 ms CB with UVR 15 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 4.7 W
Rated Current (In)
50 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
500 A
Rated Operational Voltage
600 V AC 600 V DC
Rated Uninterrupted Current (Iu)
250 A
Rated Voltage (Ur)
600 V
Recommended Screw Driver
Main Circuit M8
Release
TMF
Release Type
TM
Setting Range
50 A
Short-Circuit Performance Level
N
Standards
UL489
Sub-type
XT4
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
8 N·m
Interrupting Rating acc. to UL489
(240 V AC) 65 kA (480 V AC) 25 kA (600 V AC) 18 kA (250 V DC) 2 Poles in Series 35 kA (600 V DC) 3 Poles in Series 35 kA
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA075175R1
ABB XT4N 250 TMF 50-500 4p F F UL/CSA - Reliable Molded Case Circuit Breaker | INDSLT