The ABB XT2L 125 TMA 125-625..1250 4P FF UL/CSA is a reliable, four-pole circuit breaker with thermomagnetic release and front terminals. Suitable for a wide range of applications, it ensures high performance and safety.
Specifications for XT2L 125 TMA 125-625..1250 4p FF UL/CSA
Parameter
Value
Environmental Information
9AKK108467A6707
Product Net Width
120 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.45 kg
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
1SDH002230A1002
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour 8000 cycle
Mechanical Durability
240 cycles per hour 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 15 ms CB with UVR 15 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 11.4 W
Rated Current (In)
125 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
625â¦1250 A
Rated Operational Voltage
600 V AC 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
Product Highlights
Product Feature
1. Reliability and Efficiency The ABB XT2L 125 TMA 125-625..1250 4P FF UL/CSA is engineered to provide reliable performance in various electrical applications. Its robust design ensures consistent operation under diverse conditions.
Product Feature
2. Thermomagnetic Release Equipped with a thermomagnetic release mechanism, this circuit breaker offers advanced protection against short circuits and overloads. The TMA release ensures quick and efficient disconnection, safeguarding your equipment.
Product Feature
3. Front Terminal Connection The front terminal connection of the XT2L 125 TMA makes installation and maintenance straightforward. This design allows for easy access and reduces the time required for setup and repairs.
Product Feature
4. UL/CSA Certification Certified to UL and CSA standards, the ABB XT2L 125 TMA 125-625..1250 4P FF UL/CSA meets the highest safety and performance requirements. This certification ensures compliance with industry standards, providing peace of mind for your electrical projects.
Product Feature
5. Versatile Application Designed for a wide range of applications, from industrial settings to commercial environments, the XT2L 125 TMA is versatile and adaptable. Its compact size and high selectivity values make it an ideal choice for various electrical distribution systems.
600 V
Recommended Screw Driver
Main Circuit M6
Release
TMA
Release Type
TM
Setting Range
87.5...125 A
Short-Circuit Performance Level
L
Standards
UL489
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 200 kA (480 V AC) 100 kA (600 V AC) 35 kA (250 V DC) 2 Poles in Series 75 kA (500 V DC) 3 Poles in Series 75 kA
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA074844R1
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.
Need Help Checking This Part?
Ask about specifications, condition or a suitable alternative.
6. Environmental Sustainability ABB’s commitment to sustainability is reflected in the XT2L 125 TMA, which adheres to EU Directive 2011/65/EU and Amendment 2015/863, ensuring minimal environmental impact. This aligns with ABB’s goal of reducing waste and promoting recyclability.
Product Feature
7. High Breaking Capacity With a high breaking capacity of up to 150 kA at 220 V AC, 230 V AC, and 240 V AC, the XT2L 125 TMA provides robust protection against short circuits. This high interrupting rating ensures the circuit breaker can handle severe electrical surges effectively.
Product Feature
8. Mechanical Durability Built to withstand the rigors of frequent use, the XT2L 125 TMA has a mechanical durability of 240 cycles per hour and 25,000 cycles in total. This durability ensures the circuit breaker remains operational over extended periods, reducing the need for frequent replacements.
Product Feature
9. Compact Design The compact dimensions of the XT2L 125 TMA (120 mm width, 82.5 mm height, and 130 mm depth) make it easy to integrate into various electrical systems without taking up excessive space. This compact design also reduces the overall footprint in switchboards, saving space and improving installation flexibility.
Product Feature
10. Advanced Diagnostic Capabilities The XT2L 125 TMA features advanced diagnostic capabilities, providing ready-to-use information about the breaker's status. This enhances maintenance operations by allowing quick identification of issues, reducing downtime, and improving overall system efficiency.