The ABB XT2H 160 TMD 8-80 4p F F is a fixed four-pole moulded case circuit breaker with front terminals and a thermomagnetic release. It offers high electrical durability and is designed for transformer and generator installations, ensuring reliable power distribution and efficient operation.
Rated Instantaneous Short-Circuit Current Setting (Ii)
80 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
Product Highlights
1. High Electrical Durability
The XT2H 160 TMD 8-80 4p F F is designed to withstand 120 cycles per hour and up to 25,000 cycles, ensuring long-lasting performance in demanding electrical environments.
2. Thermal-Magnetic Release
Equipped with a thermomagnetic release, this circuit breaker provides both thermal and magnetic tripping mechanisms for enhanced safety and reliability.
3. Wide Voltage Compatibility
Compatible with various voltage ranges, including 220 V AC, 230 V AC, 380 V AC, 415 V AC, 440 V AC, 500 V AC, and 690 V AC, making it versatile for different applications.
4. High Short-Circuit Breaking Capacity
The XT2H 160 TMD 8-80 4p F F offers high short-circuit breaking capacities, including 100 kA at 220 V AC and 15 kA at 690 V AC, ensuring effective protection against electrical surges.
5. Compact Design
With dimensions of 120 mm x 130 mm x 82.5 mm and a weight of 1.45 kg, this circuit breaker is compact and easy to integrate into various electrical systems without occupying excessive space.
690 V AC 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA (230 V AC) 100 kA (240 V AC) 100 kA (380 V AC) 70 kA (415 V AC) 70 kA (440 V AC) 65 kA (500 V AC) 50 kA (525 V AC) 30 kA (690 V AC) 15 kA (250 V DC) 2 Poles in Series 70 kA (500 V DC) 3 Poles in Series 70 kA
(220 V AC) 100 kA (230 V AC) 100 kA (240 V AC) 100 kA (380 V AC) 70 kA (415 V AC) 70 kA (440 V AC) 65 kA (500 V AC) 50 kA (525 V AC) 30 kA (690 V AC) 15 kA (250 V DC) 2 Poles in Series 70 kA (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
5.6...8 A
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA067612R1
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.