ABB XT2H 160 TMA 100-1000 4p F F: High-performance, fixed four-pole moulded case circuit breaker with thermomagnetic release, rated for 100 A and 690 V AC, with a short-circuit breaking capacity of up to 100 kA.
Rated Instantaneous Short-Circuit Current Setting (Ii)
500â¦1000 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
Product Highlights
1. High Short-Circuit Breaking Capacity
The XT2H 160 TMA 100-1000 4p F F boasts a short-circuit breaking capacity of up to 100 kA, ensuring reliable protection in high-power applications.
2. Thermomagnetic Release
Equipped with a thermomagnetic release (TMA) mechanism, this circuit breaker provides fast and efficient operation under various thermal conditions.
3. Fixed Four-Pole Design
The fixed four-pole design ensures consistent performance and reliability in power distribution systems, making it suitable for transformer, generator, and installation protection applications.
4. High Electrical Durability
With an electrical durability of 120 cycles per hour and a total of 8000 cycles, this circuit breaker is designed to withstand the demands of frequent operations in industrial settings.
5. Compliance with IEC Standards
The XT2H 160 TMA 100-1000 4p F F meets IEC standards, ensuring compliance with international safety and performance regulations, providing peace of mind for users in diverse global markets.
690 V AC 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA (230 V AC) 100 kA (240 V AC) 100 kA (380 V AC) 70 kA (415 V AC) 70 kA (440 V AC) 65 kA (500 V AC) 50 kA (525 V AC) 30 kA (690 V AC) 15 kA (250 V DC) 2 Poles in Series 70 kA (500 V DC) 3 Poles in Series 70 kA
(220 V AC) 100 kA (230 V AC) 100 kA (240 V AC) 100 kA (380 V AC) 70 kA (415 V AC) 70 kA (440 V AC) 65 kA (500 V AC) 50 kA (525 V AC) 30 kA (690 V AC) 15 kA (250 V DC) 2 Poles in Series 70 kA (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMA
Release Type
TM
Setting Range
70...100 A
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA067623R1
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.
Need Help Checking This Part?