The ABB Tmax XT1H 160 TMD 50-500 4P FF is a fixed four-pole circuit breaker with front terminals and a thermomagnetic release, suitable for applications requiring high reliability and safety. It operates at a rated current of 50 A and has a rated voltage of 690 V AC/500 V DC[1][4].
Rated Instantaneous Short-Circuit Current Setting (Ii)
500 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
Product Highlights
1. Reliable Operation
The ABB Tmax XT1H 160 TMD 50-500 4P FF is designed to provide reliable operation in a wide range of electrical applications. Its thermomagnetic release ensures that the circuit breaker trips safely and efficiently in case of overcurrent conditions.
2. High Performance
With a rated current of 50 A and a rated voltage of 690 V AC/500 V DC, this circuit breaker is capable of handling demanding electrical loads. It also features a high short-circuit breaking capacity, making it suitable for applications requiring high performance.
3. Efficient Design
The front terminals of the ABB Tmax XT1H 160 TMD 50-500 4P FF make it easy to connect and disconnect the circuit breaker, reducing the time and effort required for maintenance and repairs. Its compact design also makes it ideal for space-constrained environments.
4. Compliance with Standards
The circuit breaker meets all relevant international standards, including IEC, ensuring that it is compliant with global safety and performance regulations. This makes it a reliable choice for applications across different regions.
5. Environmental Sustainability
The ABB Tmax XT1H 160 TMD 50-500 4P FF is designed with environmental sustainability in mind. It follows the EU Directive 2011/65/EU and Amendment 2015/863, ensuring that it is RoHS compliant and reduces electronic waste.
690 V AC 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 80 kA (230 V AC) 80 kA (240 V AC) 80 kA (380 V AC) 52.5 kA (415 V AC) 37.5 kA (440 V AC) 32.5 kA (500 V AC) 25 kA (525 V AC) 17.5 kA (690 V AC) 5 kA (250 V DC) 2 Poles in Series 52.5 kA (500 V DC) 3 Poles in Series 52.5 kA
(220 V AC) 100 kA (230 V AC) 100 kA (240 V AC) 100 kA (380 V AC) 70 kA (415 V AC) 70 kA (440 V AC) 65 kA (500 V AC) 50 kA (525 V AC) 35 kA (690 V AC) 10 kA (250 V DC) 2 Poles in Series 70 kA (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
35...50 A
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA067457R1
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.
Need Help Checking This Part?
Ask about specifications, condition or a suitable alternative.