The ABB XT2N 125 Breaking Part 4P FF UL/CSA is a high-performance moulded case circuit breaker designed for reliable operation in various electrical applications. It meets UL and CSA safety standards, ensuring top-notch electrical and mechanical safety.
Specifications for XT2N 125 BREAKING PART 4p F F UL/CSA
Parameter
Value
Environmental Information
9AKK108467A6707
Product Net Width
120 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.2 kg
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Breaking Part
Suitable for Product Class
SACE Tmax XT
Version
F
Electrical Durability
120 cycles per hour 8000 cycle
Mechanical Durability
240 cycles per hour 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 15 ms CB with UVR 15 ms
Order Multiple
1 piece
Rated Operational Voltage
600 V AC 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600 V
Short-Circuit Performance Level
N
Standards
UL489
Sub-type
XT2
Terminal Connection Type
Front
Interrupting Rating acc. to UL489
(240 V AC) 65 kA (480 V AC) 25 kA (600 V AC) 18 kA (250 V DC) 2 Poles in Series 35 kA (500 V DC) 3 Poles in Series 35 kA
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Product Highlights
1. Compliance with Safety Standards
The ABB XT2N 125 Breaking Part 4P FF UL/CSA is certified to meet both UL and CSA safety standards, ensuring it adheres to rigorous electrical and mechanical safety requirements.
2. High-Performance Operation
Designed for continuous operation at 125A with electronic trip units and 100A with thermal magnetic trip units, this breaker provides reliable performance in demanding electrical environments.
3. Versatile Application
Suitable for a wide range of applications, including industrial and commercial settings, this breaker offers flexibility and adaptability in various electrical systems.
4. Advanced Trip Unit Technology
Equipped with advanced electronic trip units, the XT2N 125 ensures precise and reliable tripping, minimizing the risk of electrical faults and ensuring system safety.
5. Durable Construction
Built with robust materials and designed for long-lasting performance, the XT2N 125 Breaking Part 4P FF UL/CSA is a durable addition to any electrical system, providing years of reliable service.
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA075635R1
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.
Need Help Checking This Part?