The ABB XT2H 160 TMA 80-800 3p F F is a fixed three-pole moulded case circuit breaker with front terminals and thermomagnetic release, ideal for power distribution in AC/DC environments.
Rated Instantaneous Short-Circuit Current Setting (Ii)
400â¦800 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
Product Highlights
1. High Short-Circuit Breaking Capacity
The XT2H 160 TMA 80-800 3p F F offers exceptional short-circuit breaking capacities, including 100 kA at 220 V AC, 70 kA at 380 V AC, and 15 kA at 690 V AC, ensuring reliable protection in various voltage conditions.
2. Versatile Voltage Compatibility
Designed to handle a wide range of voltages, from 220 V AC to 690 V AC, and DC voltages up to 500 V DC, making it suitable for diverse electrical applications.
3. Thermomagnetic Release
Equipped with a thermomagnetic release (TMA) mechanism, which ensures efficient and reliable operation by combining thermal and magnetic elements to trigger the circuit break.
4. High Durability
Built to withstand rigorous operational conditions, with a mechanical durability of up to 25,000 cycles and electrical durability of 8,000 cycles, ensuring long-term performance.
5. Compliance with International Standards
Meets international standards such as IEC, ensuring compliance with global safety and performance requirements, making it a trusted choice for various electrical installations.
690 V AC 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA (230 V AC) 100 kA (240 V AC) 100 kA (380 V AC) 70 kA (415 V AC) 70 kA (440 V AC) 65 kA (500 V AC) 50 kA (525 V AC) 30 kA (690 V AC) 15 kA (250 V DC) 2 Poles in Series 70 kA (500 V DC) 3 Poles in Series 70 kA
(220 V AC) 100 kA (230 V AC) 100 kA (240 V AC) 100 kA (380 V AC) 70 kA (415 V AC) 70 kA (440 V AC) 65 kA (500 V AC) 50 kA (525 V AC) 30 kA (690 V AC) 15 kA (250 V DC) 2 Poles in Series 70 kA (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMA
Release Type
TM
Setting Range
56...80 A
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA067601R1
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.
Need Help Checking This Part?
Ask about specifications, condition or a suitable alternative.