ABB XT1C 160 TMD 50-500 4p F F: A high-performance, four-pole circuit breaker with thermomagnetic release, ideal for transformer, generator, and installation protection.
Rated Instantaneous Short-Circuit Current Setting (Ii)
500 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
Product Highlights
1. High Breaking Capacity
The XT1C 160 TMD 50-500 4p F F boasts a high breaking capacity, ensuring reliable operation under various short-circuit conditions. It can handle up to 40 kA at 220-240 V AC and 25 kA at 380-440 V AC.
2. Thermomagnetic Release
Equipped with a thermomagnetic release (TMD), this circuit breaker provides efficient and reliable protection against short circuits. The TMD ensures quick and safe disconnection in case of an overload or fault.
3. Versatile Application
Designed for transformer, generator, and installation protection, the XT1C 160 TMD 50-500 4p F F is versatile and can be used in a variety of applications where high reliability is crucial. It supports both AC and DC currents.
4. Compact Design
With dimensions of 14.3 × 12.8 × 13.5 cm and a weight of 1.427 kg, the XT1C 160 TMD 50-500 4p F F is compact and easy to integrate into your system. Its front terminal connection makes installation straightforward.
5. Compliance and Certifications
The XT1C 160 TMD 50-500 4p F F meets all necessary standards and regulations, including IEC standards and CE declaration of conformity. It is also compliant with EU Directive 2011/65/EU and Amendment 2015/863.
690 V AC 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 40 kA (230 V AC) 40 kA (240 V AC) 40 kA (380 V AC) 25 kA (415 V AC) 25 kA (440 V AC) 12.5 kA (500 V AC) 9 kA (525 V AC) 8 kA (690 V AC) 4 kA (250 V DC) 2 Poles in Series 25 kA (500 V DC) 3 Poles in Series 25 kA
(220 V AC) 40 kA (230 V AC) 40 kA (240 V AC) 40 kA (380 V AC) 25 kA (415 V AC) 25 kA (440 V AC) 25 kA (500 V AC) 18 kA (525 V AC) 8 kA (690 V AC) 4 kA (250 V DC) 2 Poles in Series 25 kA (500 V DC) 3 Poles in Series 25 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
35...50 A
Short-Circuit Performance Level
C
Standards
IEC60947-2
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA067403R1
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.
Need Help Checking This Part?
Ask about specifications, condition or a suitable alternative.