The ABB XT2L 160 TMA 63-630 3p FF is a high-performance moulded case circuit breaker designed for reliable system protection in direct and alternating current networks. It features thermomagnetic release and front terminals, ensuring efficient and safe operation.
Rated Instantaneous Short-Circuit Current Setting (Ii)
300â¦630 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
Product Highlights
1. Reliable System Protection
The ABB XT2L 160 TMA 63-630 3p FF is designed to protect power distribution systems from electrical faults, ensuring the safety and integrity of your equipment.
2. High Performance
With a rated current of 160 A and a rated voltage of 690 V, this circuit breaker provides robust performance in various electrical applications.
3. Thermomagnetic Release
The thermomagnetic release mechanism ensures quick and reliable tripping in case of an electrical fault, minimizing downtime and preventing damage to your system.
4. Front Terminal Connection
The front terminal connection makes installation and maintenance easier, reducing the time and effort required for setup and troubleshooting.
5. Compliance with IEC Standards
The XT2L 160 TMA 63-630 3p FF meets IEC standards, ensuring that your system complies with international safety and performance regulations.
690 V AC 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 150 kA (230 V AC) 150 kA (240 V AC) 150 kA (380 V AC) 120 kA (415 V AC) 120 kA (440 V AC) 100 kA (500 V AC) 60 kA (525 V AC) 36 kA (690 V AC) 15 kA (250 V DC) 2 Poles in Series 85 kA (500 V DC) 3 Poles in Series 85 kA
(220 V AC) 150 kA (230 V AC) 150 kA (240 V AC) 150 kA (380 V AC) 120 kA (415 V AC) 120 kA (440 V AC) 100 kA (500 V AC) 60 kA (525 V AC) 36 kA (690 V AC) 18 kA (250 V DC) 2 Poles in Series 85 kA (500 V DC) 3 Poles in Series 85 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMA
Release Type
TM
Setting Range
44.1...63 A
Short-Circuit Performance Level
L
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA067644R1
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.
Need Help Checking This Part?
Ask about specifications, condition or a suitable alternative.