The ABB XT2L 160 TMA 40-400 3p F F is a fixed, three-pole circuit breaker with front terminals and a thermomagnetic release, offering reliable power distribution and efficient operation in a wide range of applications.
Rated Instantaneous Short-Circuit Current Setting (Ii)
300â¦400 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
Product Highlights
1. Reliable Performance
The XT2L 160 TMA 40-400 3p F F is designed to provide consistent and reliable performance, ensuring that your electrical system operates smoothly and efficiently.
2. Thermomagnetic Release
Equipped with a thermomagnetic release, this circuit breaker automatically trips in case of an overload or short circuit, ensuring the safety of your electrical system.
3. Front Terminal Connection
The front terminal connection makes it easy to install and maintain, reducing downtime and increasing overall efficiency.
4. High Breaking Capacity
With a rated ultimate short-circuit breaking capacity of 160 A, this circuit breaker can handle high short-circuit currents, making it ideal for heavy-duty applications.
5. Compliance with IEC Standards
The XT2L 160 TMA 40-400 3p F F complies with IEC standards, ensuring that it meets the highest safety and performance requirements, providing peace of mind for your electrical installations.
690 V AC 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 150 kA (230 V AC) 150 kA (240 V AC) 150 kA (380 V AC) 120 kA (415 V AC) 120 kA (440 V AC) 100 kA (500 V AC) 60 kA (525 V AC) 36 kA (690 V AC) 15 kA (250 V DC) 2 Poles in Series 85 kA (500 V DC) 3 Poles in Series 85 kA
(220 V AC) 150 kA (230 V AC) 150 kA (240 V AC) 150 kA (380 V AC) 120 kA (415 V AC) 120 kA (440 V AC) 100 kA (500 V AC) 60 kA (525 V AC) 36 kA (690 V AC) 18 kA (250 V DC) 2 Poles in Series 85 kA (500 V DC) 3 Poles in Series 85 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMA
Release Type
TM
Setting Range
28...40 A
Short-Circuit Performance Level
L
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA067642R1
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.
Need Help Checking This Part?