The ABB XT2L 160 TMA 125-1250 3P FF circuit breaker is a high-performance, three-pole device with thermomagnetic release and front terminals, ideal for power distribution systems requiring reliability and safety.
Rated Instantaneous Short-Circuit Current Setting (Ii)
60â¦1250 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
Product Highlights
Product Feature
1. High Performance and Reliability The ABB XT2L 160 TMA 125-1250 3P FF circuit breaker is engineered to provide exceptional performance and reliability, ensuring continuous operation in demanding power distribution environments.
Product Feature
2. Thermomagnetic Release Equipped with a thermomagnetic release, this circuit breaker offers a robust mechanism for interrupting short circuits, ensuring safe and efficient operation under various conditions.
Product Feature
3. Front Terminal Connection Featuring front terminals, the XT2L 160 TMA 125-1250 3P FF offers easy and convenient connection options, simplifying installation and maintenance processes.
Product Feature
4. Wide Operating Range Designed to handle a wide range of currents from 625 to 1250 A, this circuit breaker is versatile and suitable for various applications in power distribution systems.
Product Feature
5. Compliance with International Standards The XT2L 160 TMA 125-1250 3P FF is compliant with IEC standards, ensuring it meets the highest safety and performance criteria for circuit breakers, providing peace of mind for users worldwide.
690 V AC 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 150 kA (230 V AC) 150 kA (240 V AC) 150 kA (380 V AC) 120 kA (415 V AC) 120 kA (440 V AC) 100 kA (500 V AC) 60 kA (525 V AC) 36 kA (690 V AC) 15 kA (250 V DC) 2 Poles in Series 85 kA (500 V DC) 3 Poles in Series 85 kA
(220 V AC) 150 kA (230 V AC) 150 kA (240 V AC) 150 kA (380 V AC) 120 kA (415 V AC) 120 kA (440 V AC) 100 kA (500 V AC) 60 kA (525 V AC) 36 kA (690 V AC) 18 kA (250 V DC) 2 Poles in Series 85 kA (500 V DC) 3 Poles in Series 85 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMA
Release Type
TM
Setting Range
8.4...12 A
Short-Circuit Performance Level
L
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA067647R1
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.
Need Help Checking This Part?
Ask about specifications, condition or a suitable alternative.