ABB NFZ62E-21: 6NO, 2NC relay for 24-60V, 50/60Hz applications, suitable for switching auxiliary and control circuits.
Product ModelNFZ62E-21
Material Number1SBH136001R2162
Product ID84978
Stock on Request
Last updated: 8/29/2026
Key Features
1
1. Versatile Voltage RangeThe NFZ62E-21 operates within a wide voltage range of 24-60V, making it adaptable to various industrial settings.
2
2. High ReliabilityDesigned with high-quality components, this relay ensures reliable performance in demanding applications.
3
3. Flexible Contact ConfigurationWith 6 normally open (NO) and 2 normally closed (NC) contacts, the NFZ62E-21 offers flexibility in circuit configurations.
4
4. Wide Frequency CompatibilityCompatible with both 50Hz and 60Hz frequencies, this relay is suitable for use in different regions and applications.
5
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Product Net Width
45 mm
Product Net Depth / Length
110.5 mm
Product Net Height
86 mm
Product Net Weight
0.36 kg
Number of Auxiliary Contacts NO
6
Number of Auxiliary Contacts NC
2
5. Durable DesignBuilt to withstand frequent switching cycles, the NFZ62E-21 has a maximum mechanical switching frequency of 6000 cycles per hour, ensuring long-lasting performance.
Standards
IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, CSA C22.2 No. 14-13
(500 V) 2 A (690 V) 2 A (24 / 127 V) 6 A (220 / 240 V) 4 A (400 / 440 V) 3 A
Rated Short-time Withstand Current Low Voltage (Icw)
for 0.1 s 140 A for 1 s 100 A
Maximum Electrical Switching Frequency
(AC-15) 1200 cycles per hour (DC-13) 900 cycles per hour
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W (48 V) 2.8 A / 134 W (72 V) 1 A / 72 W (110 V) 0.55 A / 60 W (125 V) 0.55 A / 69 W (220 V) 0.27 A / 60 W (250 V) 0.27 A / 68 W (400 V) 0.15 A / 60 W (500 V) 0.13 A / 65 W (600 V) 0.1 A / 60 W
Rated Insulation Voltage (Ui)
acc. to IEC 60947-5-1 690 V acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Maximum Mechanical Switching Frequency
6000 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 24 ... 60 V 60 Hz 24 ... 60 V DC Operation 20 ... 60 V
Operate Time
Between Coil De-energization and NC Contact Closing 13 ... 98 ms Between Coil De-energization and NO Contact Opening 11 ... 95 ms Between Coil Energization and NC Contact Opening 38 ... 90 ms Between Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Auxiliary Circuit 11 in·lb Control Circuit 11 in·lb
Ambient Air Temperature
Close to Contactor for Storage -60 ... +80 °C Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: B1 25 g Open, Shock Direction: B1 5 g Shock Direction: A 30 g Shock Direction: B2 15 g Shock Direction: C1 25 g Shock Direction: C2 25 g
Resistance to Vibrations
4g Closed Position & 2g Open position 5 ... 300 Hz