Short Description: ABB XT1S 125 TMF 60-600 4p F F UL/CSA - High-performance, 4-pole circuit breaker with thermomagnetic release, UL/CSA certified for safety and reliability.
Specifications for XT1S 125 TMF 60-600 4p F F UL/CSA
Parameter
Value
Environmental Information
9AKK108467A6707
Product Net Width
101.6 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.4 kg
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
1SDH001295R0080
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour 8000 cycle
Mechanical Durability
240 cycles per hour 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 15 ms CB with UVR 15 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 3.9 W
Rated Current (In)
60 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
700 A
Rated Operational Voltage
600Y/347 V AC 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
Product Highlights
1. High Performance and Reliability
The ABB XT1S 125 TMF 60-600 4p F F UL/CSA is designed to provide reliable performance in a wide range of applications, ensuring consistent operation and minimal downtime.
2. Thermomagnetic Release (TMF)
Equipped with a thermomagnetic release (TMF) mechanism, this circuit breaker offers efficient and safe operation under various conditions, including thermal and magnetic stresses.
3. UL/CSA Certification
Meets the stringent safety standards of UL (Underwriters Laboratories) and CSA (Canadian Standards Association), ensuring compliance with regulatory requirements for electrical safety.
4. Versatile Application
Suitable for 4-pole applications, this circuit breaker can handle a wide range of electrical loads, making it versatile for various industrial and commercial settings.
5. Durable Design
Constructed with high-quality materials, the XT1S 125 TMF 60-600 4p F F UL/CSA is built to withstand harsh environmental conditions and prolonged use, extending its lifespan and reducing maintenance needs.
600Y/347 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
60 A
Short-Circuit Performance Level
S
Standards
UL489
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 65 kA (480 V AC) 35 kA (600Y / 347 V AC) 22 kA (250 V DC) 2 Poles in Series 42 kA (500 V DC) 4 Poles in Series Kind 50 kA
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA074687R1
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.
Need Help Checking This Part?
Ask about specifications, condition or a suitable alternative.