Short Description: ABB XT1H 125 TMF 80-800 3P F F UL/CSA: High-performance, three-pole circuit breaker with thermal-magnetic fixed (TMF) operation, meeting UL/CSA standards for reliable and safe electrical distribution.
Specifications for XT1H 125 TMF 80-800 3p F F UL/CSA
Parameter
Value
Environmental Information
9AKK108467A6707
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.1 kg
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
1SDH001295R0008
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour 8000 cycle
Mechanical Durability
240 cycles per hour 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 15 ms CB with UVR 15 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 4.8 W
Rated Current (In)
80 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
800 A
Rated Operational Voltage
600Y/347 V AC 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
Product Highlights
1. High Performance and Reliability
The XT1H 125 TMF 80-800 3P F F UL/CSA circuit breaker is designed to provide reliable performance under various electrical conditions, ensuring continuous operation without interruptions.
2. Thermal-Magnetic Fixed (TMF) Operation
Equipped with a thermal-magnetic fixed (TMF) release, this circuit breaker offers both thermal and magnetic tripping mechanisms, providing enhanced protection against overloads and short circuits.
3. UL/CSA Certification
Meets the stringent standards of UL (Underwriters Laboratories) and CSA (Canadian Standards Association), ensuring compliance with safety regulations and reliability in electrical distribution systems.
4. High Interrupting Capacity
With an interrupting rating of up to 25 kA at 600Y/347 V AC, this circuit breaker can handle high short-circuit currents, making it suitable for demanding electrical applications.
5. Ease of Installation and Maintenance
Designed with front terminal connections and a recommended screw driver (TMF), the XT1H 125 TMF 80-800 3P F F UL/CSA circuit breaker offers ease of installation and maintenance, reducing downtime and increasing operational efficiency.
600Y/347 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
80 A
Short-Circuit Performance Level
H
Standards
UL489
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 100 kA (480 V AC) 65 kA (600Y / 347 V AC) 25 kA (250 V DC) 2 Poles in Series 50 kA (500 V DC) 4 Poles in Series Kind 50 kA
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA074704R1
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.