The ABB XT2H 160 TMA 50-500 3p F F is a high-performance moulded case circuit breaker with a thermomagnetic release and front terminals, suitable for AC/DC applications up to 690V AC and 500V DC.
Rated Instantaneous Short-Circuit Current Setting (Ii)
300â¦500 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
Product Highlights
Product Feature
1. High Reliability and Safety The XT2H 160 TMA 50-500 3p F F is designed with a thermomagnetic release (TMA) for reliable operation and meets IEC standards for safety, ensuring high reliability and protection against electrical faults.
Product Feature
2. Versatile Application This circuit breaker is suitable for both AC and DC applications, making it versatile for various electrical systems. It supports currents from 50 to 500A and voltages up to 690V AC and 500V DC.
Product Feature
3. Efficient Power Distribution With its circular design and front terminals, the XT2H 160 TMA 50-500 3p F F facilitates efficient power distribution. It is ideal for use in power distribution systems, including transformer and generator installations.
Product Feature
4. Durable Construction The product is built to withstand high operational cycles. It has an electrical durability of 120 cycles per hour and a mechanical durability of 240 cycles per hour, ensuring long-lasting performance in demanding environments.
Product Feature
5. Compliance with Environmental Standards The XT2H 160 TMA 50-500 3p F F complies with EU Directive 2011/65/EU and Amendment 2015/863, ensuring it meets RoHS (Restriction of Hazardous Substances) standards. This makes it an environmentally friendly choice for your electrical needs.
690 V AC 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA (230 V AC) 100 kA (240 V AC) 100 kA (380 V AC) 70 kA (415 V AC) 70 kA (440 V AC) 65 kA (500 V AC) 50 kA (525 V AC) 30 kA (690 V AC) 15 kA (250 V DC) 2 Poles in Series 70 kA (500 V DC) 3 Poles in Series 70 kA
(220 V AC) 100 kA (230 V AC) 100 kA (240 V AC) 100 kA (380 V AC) 70 kA (415 V AC) 70 kA (440 V AC) 65 kA (500 V AC) 50 kA (525 V AC) 30 kA (690 V AC) 15 kA (250 V DC) 2 Poles in Series 70 kA (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMA
Release Type
TM
Setting Range
35...50 A
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA067599R1