ABB's XT2V 125 TMF 40-400 3P F F UL/CSA circuit breaker offers reliable electrical distribution with a thermomagnetic trip unit and UL/CSA certification for safety.
Product ModelXT2V 125 TMF 40-400 3p F F UL/CSA
Material Number1SDA074850R1
Product ID84224
Stock on Request
Last updated: 8/29/2026
Key Features
1
1. Reliable Electrical DistributionThe XT2V 125 TMF 40-400 3P F F UL/CSA circuit breaker ensures consistent and reliable electrical distribution, making it ideal for various industrial applications.
2
2. Thermomagnetic Trip UnitEquipped with a thermomagnetic trip unit, this circuit breaker provides enhanced safety by automatically tripping in case of excessive heat or current, preventing electrical fires and damage.
3
3. UL/CSA CertificationCertified by UL (Underwriters Laboratories) and CSA (Canadian Standards Association), this product meets stringent safety standards, ensuring compliance with regulatory requirements.
4
4. Front Terminal DesignThe front terminal design of the XT2V 125 TMF 40-400 3P F F UL/CSA makes installation and maintenance easier, reducing downtime and increasing efficiency.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Environmental Information
9AKK108467A6707
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.1 kg
Circuit Breaker Type to be Associated
Power Distribution
5
5. High-Performance CapabilityWith a rating of 40A at 600V, this circuit breaker is capable of handling high electrical loads, making it suitable for demanding industrial environments.
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
1SDH002230A1001
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour 8000 cycle
Mechanical Durability
240 cycles per hour 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 15 ms CB with UVR 15 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 3.7 W
Rated Current (In)
40 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
400 A
Rated Operational Voltage
600 V AC 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
600 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
40 A
Short-Circuit Performance Level
V
Standards
UL489
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 200 kA (480 V AC) 150 kA (600 V AC) 42 kA (250 V DC) 2 Poles in Series 85 kA (500 V DC) 3 Poles in Series 85 kA
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA074850R1