The ABB XT2L 160 TMA 50-500 4P FF is a thermomagnetic molded case circuit breaker (MCCB) designed for reliable power distribution. It offers a 4-pole configuration and a current range of 50-500 A, making it suitable for a wide range of applications.
Rated Instantaneous Short-Circuit Current Setting (Ii)
300â¦500 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
Product Highlights
1. Reliable Performance
The XT2L 160 TMA 50-500 4P FF is built with high-quality materials and advanced thermomagnetic technology, ensuring reliable performance and consistent operation under various load conditions.
2. Easy Installation
Featuring front terminals, this MCCB simplifies the installation process, reducing the time and effort required for setup. The design also allows for easy maintenance and replacement of components.
3. Wide Current Range
With a current range of 50-500 A, the XT2L 160 TMA 50-500 4P FF is versatile and can be used in a variety of applications, from small to large-scale electrical systems.
4. High Safety Standards
Designed with safety in mind, this MCCB adheres to stringent safety standards, ensuring that it operates within safe parameters and reduces the risk of electrical accidents.
5. Durable Construction
Constructed with durable materials, the XT2L 160 TMA 50-500 4P FF is built to last, providing long-term reliability and minimizing the need for frequent replacements or repairs.
690 V AC 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 150 kA (230 V AC) 150 kA (240 V AC) 150 kA (380 V AC) 120 kA (415 V AC) 120 kA (440 V AC) 100 kA (500 V AC) 60 kA (525 V AC) 36 kA (690 V AC) 15 kA (250 V DC) 2 Poles in Series 85 kA (500 V DC) 3 Poles in Series 85 kA
(220 V AC) 150 kA (230 V AC) 150 kA (240 V AC) 150 kA (380 V AC) 120 kA (415 V AC) 120 kA (440 V AC) 100 kA (500 V AC) 60 kA (525 V AC) 36 kA (690 V AC) 18 kA (250 V DC) 2 Poles in Series 85 kA (500 V DC) 3 Poles in Series 85 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMA
Release Type
TM
Setting Range
35...50 A
Short-Circuit Performance Level
L
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA067664R1
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.