Reliable manual motor starter with adjustable current settings, phase loss sensitivity, and a disconnect function. Suitable for single motor applications and group installations.
Product ModelMS132-20KT
Material Number1SAM340010R1013
Product ID83959
Stock on Request
Last updated: 8/29/2026
Key Features
1
1. Reliable ProtectionThe ABB MS132-20KT provides comprehensive protection against short circuits, overloads, and phase failures, ensuring the safety and reliability of your motor installations.
2
2. Adjustable Current SettingsWith adjustable current settings, you can customize the device to meet the specific needs of your motor, ensuring optimal performance and protection.
3
3. Phase Loss SensitivityThe device is designed with phase loss sensitivity, which detects and responds to changes in the phase, providing quick and reliable protection against potential hazards.
4
4. Disconnect FunctionThe MS132-20KT features a disconnect function, allowing for safe isolation of the installation and supply, making it easier to perform maintenance and repairs.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Product Net Width
45 mm
Product Net Height
112 mm
Product Net Depth / Length
87 mm
Product Net Weight
0.317 kg
Rated Service Short-Circuit Breaking Capacity (Ics)
(230 V AC) 100 kA (400 V AC) 100 kA (440 V AC) 30 kA
5. Versatile ApplicationsSuitable for both single motor applications and group installations, the MS132-20KT is a versatile solution for various motor protection needs, including tap conductor protection and type E and F combination motor controllers.
Rated Instantaneous Short-Circuit Current Setting (Ii)
400 A
Setting Range
16 ... 20 A
Rated Operational Voltage
Main Circuit 690 V AC
Rated Operational Current (Ie)
20 A
Rated Frequency (f)
Main Circuit 50 Hz Main Circuit 60 Hz
Operating Frequency (fsw)
0 ... 400 Hz
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 6 kV
Rated Insulation Voltage (Ui)
690 V
Power Loss
at Rated Operating Conditions per Pole 1.0 ... 1.6 W
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kA Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
Maximum Operating Voltage UL/CSA
Main Circuit 600 V AC
Horsepower Rating UL/CSA
(120 V AC) Single Phase 1.5 Hp (220 ... 240 V AC) Single Phase 3 Hp
Full Load Amps Motor Use
(120 V AC) Single Phase 20 A (220 ... 240 V AC) Single Phase 17 A
Locked Rotor Amps
(120 V AC) Single Phase 120 A (220 ... 240 V AC) Single Phase 120 A