The ABB XT1H 125 TMF 110-1100 4P FF UL/CSA is a high-performance, four-pole molded case circuit breaker with a thermal-magnetic trip unit, designed for UL and CSA certification, ensuring safe and efficient power distribution.
Specifications for XT1H 125 TMF 110-1100 4p F F UL/CSA
Parameter
Value
Environmental Information
9AKK108467A6707
Product Net Width
101.6 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.4 kg
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
1SDH001295R0080
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour 8000 cycle
Mechanical Durability
240 cycles per hour 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 15 ms CB with UVR 15 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 8.3 W
Rated Current (In)
110 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
1100 A
Rated Operational Voltage
600Y/347 V AC 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
Product Highlights
1. Reliable Protection
The XT1H 125 TMF 110-1100 4P FF UL/CSA features a thermal-magnetic trip unit, providing reliable protection against short circuits and overloads, ensuring the safety of your electrical system.
2. Compliance with Standards
Certified to UL and CSA standards, this circuit breaker meets the highest safety and performance requirements, making it suitable for a wide range of applications.
3. Efficient Power Distribution
Designed for efficient power distribution, the XT1H 125 TMF 110-1100 4P FF UL/CSA ensures that your electrical system operates smoothly and reliably, minimizing downtime and maximizing productivity.
4. Compact Design
With a compact design, this circuit breaker fits seamlessly into your switchboard, saving space and reducing installation complexity. Its front terminals provide easy access for maintenance and troubleshooting.
5. High Interrupting Capacity
The XT1H 125 TMF 110-1100 4P FF UL/CSA has a high interrupting capacity of 25 kA at 600Y/347 V AC, making it capable of handling high short-circuit currents, ensuring the integrity of your electrical system.
600Y/347 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
110 A
Short-Circuit Performance Level
H
Standards
UL489
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 100 kA (480 V AC) 65 kA (600Y / 347 V AC) 25 kA (250 V DC) 2 Poles in Series 50 kA (500 V DC) 4 Poles in Series Kind 50 kA
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA074722R1
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.