The ABB XT2H 125 TMF 20-400 3P F F UL/CSA is a high-performance, three-pole molded case circuit breaker designed for reliable operation in various electrical applications. It features a thermal-magnetic trip and meets UL/CSA standards for safety and efficiency.
Specifications for XT2H 125 TMF 20-400 3p F F UL/CSA
Parameter
Value
Environmental Information
9AKK108467A6707
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.1 kg
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
1SDH002230A1001
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour 8000 cycle
Mechanical Durability
240 cycles per hour 25000 cycle
Number of Poles
3P
Opening Time
CB with SOR 15 ms CB with UVR 15 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 1.6 W
Rated Current (In)
20 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
400 A
Rated Operational Voltage
600 V AC 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
Product Highlights
1. Reliable Operation
The XT2H 125 TMF 20-400 3P F F UL/CSA is designed to provide reliable operation in a wide range of electrical applications, ensuring consistent performance and minimal downtime.
2. Thermal-Magnetic Trip
Equipped with a thermal-magnetic trip, this circuit breaker offers enhanced protection against overcurrents and short circuits, ensuring the safety of your electrical system.
3. UL/CSA Certification
Meets the stringent safety standards of UL and CSA, providing you with the assurance of a product that is built to last and operates safely.
4. High Interrupting Capacity
With an interrupting rating of 25 kA at 600 V AC, this circuit breaker can handle high short-circuit currents, making it ideal for demanding electrical environments.
5. Sustainable Design
ABB's commitment to sustainability is evident in the XT2H 125 TMF 20-400 3P F F UL/CSA, which is designed with recyclability in mind and adheres to circular design principles, reducing waste and environmental impact.
600 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
20 A
Short-Circuit Performance Level
H
Standards
UL489
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 150 kA (480 V AC) 65 kA (600 V AC) 25 kA (250 V DC) 2 Poles in Series 65 kA (500 V DC) 3 Poles in Series 65 kA
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA074790R1