The ABB XT2H 160 TMA 160-1600 3p F F is a fixed three-pole circuit breaker with front terminals and thermomagnetic release, designed for power distribution applications. It features a rated insulation voltage of 1000 V and a rated instantaneous short-circuit current setting of 800-1600 A[1][3].
Rated Instantaneous Short-Circuit Current Setting (Ii)
800â¦1600 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
Product Highlights
1. High Electrical Durability
The XT2H 160 TMA 160-1600 3p F F can withstand 120 cycles per hour and up to 8000 cycles, ensuring reliable operation in demanding electrical environments.
2. Robust Short-Circuit Performance
With a rated service short-circuit breaking capacity of up to 100 kA at various voltage levels, this circuit breaker provides excellent protection against short circuits.
3. Thermomagnetic Release
Equipped with a thermomagnetic release (TMA), this circuit breaker ensures safe and efficient operation by automatically tripping in case of an overload or short circuit.
4. Front Terminal Connection
The front terminal connection makes installation and maintenance easier, reducing downtime and increasing overall efficiency.
5. Compliance with International Standards
The XT2H 160 TMA 160-1600 3p F F meets IEC standards, ensuring compliance with international safety and performance requirements.
690 V AC 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 100 kA (230 V AC) 100 kA (240 V AC) 100 kA (380 V AC) 70 kA (415 V AC) 70 kA (440 V AC) 65 kA (500 V AC) 50 kA (525 V AC) 30 kA (690 V AC) 15 kA (250 V DC) 2 Poles in Series 70 kA (500 V DC) 3 Poles in Series 70 kA
(220 V AC) 100 kA (230 V AC) 100 kA (240 V AC) 100 kA (380 V AC) 70 kA (415 V AC) 70 kA (440 V AC) 65 kA (500 V AC) 50 kA (525 V AC) 30 kA (690 V AC) 15 kA (250 V DC) 2 Poles in Series 70 kA (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMA
Release Type
TM
Setting Range
112...160 A
Short-Circuit Performance Level
H
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA067604R1
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.