ABB XT2H 125 TMF 35-400 4p F F UL/CSA: A high-performance, 4-pole molded case circuit breaker with electronic and thermal magnetic trips, certified for UL and CSA standards, ensuring optimal safety and efficiency.
Specifications for XT2H 125 TMF 35-400 4p F F UL/CSA
Parameter
Value
Environmental Information
9AKK108467A6707
Product Net Width
120 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.45 kg
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
1SDH002230A1002
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour 8000 cycle
Mechanical Durability
240 cycles per hour 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 15 ms CB with UVR 15 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 2.8 W
Rated Current (In)
35 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
400 A
Rated Operational Voltage
600 V AC 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
Product Highlights
1. Certified Safety Standards
The ABB XT2H 125 TMF 35-400 4p F F UL/CSA is certified for both UL and CSA standards, ensuring it meets stringent safety requirements in the U.S. and Canada.
2. Advanced Trip Mechanisms
Equipped with both electronic and thermal magnetic trip units, this circuit breaker provides reliable protection against overcurrents and faults, ensuring the integrity of electrical systems.
3. Versatile Application
Designed for a wide range of applications, from distribution boards to sub-switchboards, the XT2H 125 TMF 35-400 4p F F UL/CSA offers flexibility in installation and usage.
4. High Performance
With a trip range of 35 to 400 amps, this circuit breaker provides robust protection for electrical circuits, ensuring they operate within safe parameters.
5. Compact Design
Featuring a compact design, the XT2H 125 TMF 35-400 4p F F UL/CSA is ideal for space-constrained installations, making it a versatile choice for various electrical projects.
600 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
35 A
Short-Circuit Performance Level
H
Standards
UL489
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 150 kA (480 V AC) 65 kA (600 V AC) 25 kA (250 V DC) 2 Poles in Series 65 kA (500 V DC) 3 Poles in Series 65 kA
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA074807R1
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.
Need Help Checking This Part?
Ask about specifications, condition or a suitable alternative.