The ABB XT2L 160 TMD 8-80 3p FF is a fixed three-pole moulded case circuit breaker with front terminals and a thermomagnetic release. It offers reliable short-circuit protection and is suitable for transformer and generator installations.
Rated Instantaneous Short-Circuit Current Setting (Ii)
80 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
Product Highlights
1. Reliable Short-Circuit Protection
The XT2L 160 TMD 8-80 3p FF provides robust short-circuit protection with a rated service short-circuit breaking capacity of up to 150 kA at 220-240 V AC and 120 kA at 380-440 V AC.
2. Thermomagnetic Release
Equipped with a thermomagnetic release (TMD), this circuit breaker ensures safe and precise operation under various conditions, including high short-circuit currents.
3. Front Terminal Connection
The front terminal connection type (F) makes installation and maintenance easier, providing a secure and efficient connection solution.
4. Environmental Compliance
The product adheres to strict environmental standards, including RoHS compliance and a recyclability rate of 58.1% as per EN45555.
5. Versatile Application
Designed for transformer and generator installations, the XT2L 160 TMD 8-80 3p FF is versatile and can handle a wide range of electrical applications, including AC and DC currents.
690 V AC 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 150 kA (230 V AC) 150 kA (240 V AC) 150 kA (380 V AC) 120 kA (415 V AC) 120 kA (440 V AC) 100 kA (500 V AC) 60 kA (525 V AC) 36 kA (690 V AC) 15 kA (250 V DC) 2 Poles in Series 85 kA (500 V DC) 3 Poles in Series 85 kA
(220 V AC) 150 kA (230 V AC) 150 kA (240 V AC) 150 kA (380 V AC) 120 kA (415 V AC) 120 kA (440 V AC) 100 kA (500 V AC) 60 kA (525 V AC) 36 kA (690 V AC) 18 kA (250 V DC) 2 Poles in Series 85 kA (500 V DC) 3 Poles in Series 85 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
5.6...8 A
Short-Circuit Performance Level
L
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA067635R1
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.
Need Help Checking This Part?