ABB's XT2L 160 TMD 5-50 3P FF circuit breaker ensures reliable power distribution with a thermomagnetic release and front terminals, meeting IEC standards for high durability and safety.
Rated Instantaneous Short-Circuit Current Setting (Ii)
50 A
Rated Insulation Voltage (Ui)
1000 V
Rated Operational Voltage
Product Highlights
1. Reliable Power Distribution
The XT2L 160 TMD 5-50 3P FF circuit breaker provides consistent and reliable power distribution, ensuring minimal downtime and maximum efficiency.
2. Thermomagnetic Release
Equipped with a thermomagnetic release (TMD), this circuit breaker offers enhanced safety by automatically tripping in case of overheating or short circuits, protecting your equipment and personnel.
3. Front Terminal Connection
The front terminal connection type (FF) simplifies installation and maintenance, allowing for easy access and connection of wires without the need for rear access.
4. High Durability
Designed to withstand heavy usage, this circuit breaker is rated for 240 cycles per hour and 25,000 cycles in total, ensuring it can handle demanding electrical environments.
5. IEC Compliance
Meets IEC standards, ensuring that the XT2L 160 TMD 5-50 3P FF circuit breaker adheres to international safety and performance regulations, providing peace of mind for your electrical installations.
690 V AC 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 150 kA (230 V AC) 150 kA (240 V AC) 150 kA (380 V AC) 120 kA (415 V AC) 120 kA (440 V AC) 100 kA (500 V AC) 60 kA (525 V AC) 36 kA (690 V AC) 15 kA (250 V DC) 2 Poles in Series 85 kA (500 V DC) 3 Poles in Series 85 kA
(220 V AC) 150 kA (230 V AC) 150 kA (240 V AC) 150 kA (380 V AC) 120 kA (415 V AC) 120 kA (440 V AC) 100 kA (500 V AC) 60 kA (525 V AC) 36 kA (690 V AC) 18 kA (250 V DC) 2 Poles in Series 85 kA (500 V DC) 3 Poles in Series 85 kA
Rated Uninterrupted Current (Iu)
160 A
Rated Voltage (Ur)
690 V
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
3.5...5 A
Short-Circuit Performance Level
L
Standards
IEC60947-2
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA067633R1
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.
Need Help Checking This Part?
Ask about specifications, condition or a suitable alternative.