Short Description: ABB's XT2H 125 TMA 110-550..1100 4P F F UL/CSA circuit breaker features a thermal-magnetic trip unit, 65kA short circuit rating, and compliance with UL and CSA standards for reliable and safe electrical distribution.
Specifications for XT2H 125 TMA 110-550..1100 4p F F UL/CSA
Parameter
Value
Environmental Information
9AKK108467A6707
Product Net Width
120 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.45 kg
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
1SDH002230A1002
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour 8000 cycle
Mechanical Durability
240 cycles per hour 25000 cycle
Number of Poles
4P
Opening Time
CB with SOR 15 ms CB with UVR 15 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 8.8 W
Rated Current (In)
110 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
550â¦1100 A
Rated Operational Voltage
600 V AC 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
Product Highlights
1. High Performance and Reliability
The XT2H 125 TMA 110-550..1100 4P F F UL/CSA circuit breaker is designed to provide reliable performance under various electrical conditions, ensuring consistent operation and minimal downtime.
2. Advanced Trip Unit
Equipped with a thermal-magnetic trip unit (TMA), this circuit breaker offers adjustable settings for precise control over short-circuit currents, enhancing safety and efficiency.
3. Compliance with International Standards
Meets the stringent standards of UL (Underwriters Laboratories) and CSA (Canadian Standards Association), ensuring compliance with global safety regulations.
4. High Short-Circuit Rating
With a short-circuit rating of 65kA at 480V AC, this circuit breaker is capable of handling high fault currents, making it suitable for demanding electrical applications.
5. Compact Design
The compact design of the XT2H 125 TMA 110-550..1100 4P F F UL/CSA circuit breaker allows for easy integration into various electrical systems, minimizing space requirements while maximizing functionality.
600 V
Recommended Screw Driver
Main Circuit M6
Release
TMA
Release Type
TM
Setting Range
77...110 A
Short-Circuit Performance Level
H
Standards
UL489
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 150 kA (480 V AC) 65 kA (600 V AC) 25 kA (250 V DC) 2 Poles in Series 65 kA (500 V DC) 3 Poles in Series 65 kA
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA074815R1
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.
Need Help Checking This Part?