The XT1B 160 TMD 160-1600 4P F F InN=100% is a robust, four-pole moulded case circuit breaker designed for transformer and generator installations. It includes thermomagnetic release and front terminals, ensuring reliable and efficient operation. Fully rated for neutral, this circuit breaker meets the highest standards of electrical durability and safety.
Specifications for XT1B160 TMD160/1600 FEF 4P N =100%
Parameter
Value
Environmental Information
9AKK108467A6707
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
Current Type
AC/DC
Electrical Durability
8000 cycle 120 cycles per hour
Mechanical Durability
25000 cycle 240 cycles per hour
Number of Poles
4P
Power Loss
at Rated Operating Conditions per Pole 15 W
Rated Current (In)
160 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 25 kA (230 V AC) 25 kA (240 V AC) 25 kA (380 V AC) 18 kA (415 V AC) 18 kA (440 V AC) 11.5 kA (500 V AC) 8 kA (525 V AC) 6 kA (690 V AC) 3 kA (250 V DC) 2 Poles in Series 18 kA (500 V DC) 3 Poles in Series 18 kA
(220 V AC) 25 kA (230 V AC) 25 kA (240 V AC) 25 kA (380 V AC) 18 kA (415 V AC) 18 kA (440 V AC) 15 kA (500 V AC) 8 kA (525 V AC) 6 kA (690 V AC) 3 kA (250 V DC) 2 Poles in Series 18 kA (500 V DC) 3 Poles in Series 18 kA
Rated Uninterrupted Current (Iu)
160 A
Release
TMD
Release Type
TM
Short-Circuit Performance Level
B
Standards
IEC60947-2 GB/T 14028.2
Product Highlights
1. High Performance and Reliability
The XT1B 160 TMD 160-1600 4P F F InN=100% is engineered to provide exceptional performance and reliability, making it a trusted choice for critical applications like transformer and generator installations.
2. Thermomagnetic Release
Equipped with a thermomagnetic release mechanism, this circuit breaker ensures safe and efficient operation under various electrical conditions, including short circuits and overloads.
3. Front Terminal Connection
The front terminal connection simplifies installation and maintenance, reducing downtime and increasing overall efficiency. The terminals are designed for easy access and secure connections.
4. Fully Rated for Neutral
This circuit breaker is fully rated for neutral, ensuring that it can handle the full range of electrical currents without compromising on safety or performance. This feature is particularly important in applications where neutral currents are significant.
5. Compliance with IEC Standards
The XT1B 160 TMD 160-1600 4P F F InN=100% complies with IEC standards, ensuring that it meets the highest international safety and performance criteria. This compliance provides peace of mind for users and ensures that the product is compatible with a wide range of electrical systems.
Sub-type
XT1
Terminal Connection Type
Front Extended
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Manufacturer ID
2TFH100031R1001
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.
Need Help Checking This Part?