Protect your installations with the ABB F204 AC-25/0.1 IEC RCCB, providing robust earth fault protection and compliance with IEC/EN 61008 standards.
Product ModelF204 AC-25/0.1 IEC
Material Number2CSF204005R2250
Product ID82262
Stock on Request
Last updated: 8/29/2026
Key Features
1
1. Advanced Earth Fault ProtectionThe ABB F204 AC-25/0.1 IEC RCCB is designed to protect against sinusoidal alternating and direct pulsating earth fault currents, ensuring your installations are safeguarded against potential hazards.
2
2. Compliance with IEC/EN 61008 StandardsThis RCCB meets the stringent requirements of IEC/EN 61008, ensuring it is certified for use in residential, commercial, and industrial settings, providing you with peace of mind and regulatory compliance.
3
3. Reliable and Durable DesignConstructed with high-quality materials, the F204 AC-25/0.1 IEC RCCB is built to last, offering reliable performance over time and minimizing the need for frequent replacements.
4
4. Versatile Installation OptionsThe product is designed to be flexible, allowing for easy installation in various settings. It is particularly useful for wiring with busbars or cables and supports special needs where the neutral pole is on the left.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Standards
IEC 61008
Type of Residual Current
Type AC
Rated Voltage (Ur)
230/400 V
Rated Operational Voltage
230 / 400 V AC
Rated Insulation Voltage (Ui)
500 V
Test Voltage (Ut)
110-254 V
5
5. Enhanced Safety FeaturesWith additional protection against indirect contacts and direct contacts (with I∆n=30 mA), this RCCB ensures comprehensive safety for your electrical systems, reducing the risk of electrical shocks and fires.
Rated Impulse Withstand Voltage (Uimp)
4 kV
Input Voltage Type
AC
Rated Current (In)
25 A
Rated Residual Current
100 mA
Rated Conditional Short-Circuit Current (Inc)
10 kA
Maximum Surge Current
0.25 kA
Leakage Current Type
AC
Frequency (f)
50/60 Hz
Rated Frequency (f)
50 ⦠60 Hz
Power Loss
at Rated Operating Conditions per Pole 1.3 W
Power Supply Connection
Arbitrary
Electrical Endurance
10000 cycle
Number of Poles
4
Number of Modular Spacings per DIN Rail
4
Operating Characteristic
Instantaneous
Position of Neutral Terminals
Right
Tightening Torque
2.8 N·m
Accessory Type