Precise ControlThe CPE14-M1BH-5JS-QS-6 offers precise control in pneumatic systems, ensuring reliable operation and minimal leakage.
2
Non-Detenting Manual OverrideThe valve features a non-detenting manual override, allowing for easy manual operation without compromising the solenoid's function.
3
External Pilot AirThe external pilot air connection enhances the valve's functionality, enabling it to be piloted by external air sources for added versatility.
4
High Flow RatesWith a standard nominal flow rate of up to 3,200 liters per minute, this valve is suitable for high-demand applications in various industries.
5
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Valve function
5/2, bistable
Actuation type
Electrical
Width
14mm
Standard nominal flow rate
400l/min
Pneumatic working port
QS-6
Operating voltage
24V DC
Durable ConstructionBuilt with durable materials and designed to withstand shock tests (FN942017-4 and EN 60068-2-6), this valve ensures long-lasting performance in demanding environments.
Operating pressure
-0.9bar 10bar
Structural design
Piston gate valve
Certification
c UL us - Recognized (OL)
Maritime classification
See certificate
Certificate issuing authority
DNV-TAA000032X UL MH19482
Degree of protection
IP65 With plug socket as per IEC 60529
Nominal width
6mm
Exhaust air function
With flow control option
Sealing principle
Soft
Mounting position
Any
Manual override
Detenting via accessory Non-detenting
Type of control
Pilot-controlled
Pilot air supply port
External
Flow direction
Reversible
Symbol
00991016
Valve position ID
Label holder
Lap
Overlap
Pilot pressure MPa
0.2MPa 0.8MPa
Pilot pressure
2bar 8bar
Changeover time
13ms
Duty cycle
100% in combination with holding current reduction
Max. positive test pulse with 0 signal
1200μs
Max. negative test pulse on 1 signal
900μs
Coil characteristics
24 V DC: 1.28 W
Permissible voltage fluctuations
-15 % / +10 %
Operating medium
Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media
Operation with oil lubrication possible (required for further use)
Vibration resistance
Transport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6
Shock resistance
Shock test with severity level 2 as per FN 942017-5 and EN 60068-2-27