The ABB F204 A-80/0.5 RCD provides smart protection against fault currents to earth, ensuring safety and reliability in commercial and industrial settings.
Product ModelF204 A-80/0.5
Material Number2CSF204101R4800
Product ID76807
Stock on Request
Last updated: 8/29/2026
Key Features
1
Feature1. Instantaneous and Selective Protection The F204 A-80/0.5 RCD offers instantaneous protection against fault currents to earth, ensuring quick response in emergency situations. Its selective protection feature minimizes unnecessary tripping, reducing downtime and improving overall efficiency.
2
Feature2. Advanced Safety Features Equipped with advanced safety features, this RCD ensures that your people and installations are protected from electrical hazards. Its robust design and reliable performance make it a trusted choice for critical applications.
3
Feature3. Wide Application Range Suitable for both commercial and industrial settings, the F204 A-80/0.5 RCD is versatile and adaptable to various electrical configurations. Its compact design makes it easy to integrate into existing systems.
4
Feature4. High Reliability and Durability Built with high-quality materials and designed for long-lasting performance, the F204 A-80/0.5 RCD offers reliable protection over time. Its robust construction ensures it can withstand harsh environmental conditions.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Standards
IEC/EN 61008 UL 1053
Type of Residual Current
Type A
Rated Voltage (Ur)
230/400 V
Rated Operational Voltage
230 / 400 V AC
Rated Insulation Voltage (Ui)
500 V
Test Voltage (Ut)
110-254 V
5
Feature5. Compliance with International Standards The F204 A-80/0.5 RCD complies with international standards such as IEC, ensuring that it meets the highest safety and performance requirements. This certification provides peace of mind for users, knowing that their electrical systems are protected by a globally recognized brand.
Rated Impulse Withstand Voltage (Uimp)
4 kV
Input Voltage Type
AC
Rated Current (In)
80 A
Rated Residual Current
500 mA
Rated Conditional Short-Circuit Current (Inc)
10 kA
Leakage Current Type
A
Frequency (f)
50/60 Hz
Rated Frequency (f)
50 ⦠60 Hz
Power Loss
at Rated Operating Conditions per Pole 5.3 W
Power Supply Connection
Arbitrary
Electrical Endurance
10000 cycle
Number of Poles
4
Number of Modular Spacings per DIN Rail
4
Operating Characteristic
Instantaneous
Position of Neutral Terminals
Right
Tightening Torque
2.8 N·m
Accessory Type