Short Description: ABB's XT2H 125 TMF 70-700 3P F F UL/CSA is a three-pole moulded case circuit breaker with front terminals and thermomagnetic release, certified for UL and CSA standards, ensuring high safety and reliability in electrical distribution.
Specifications for XT2H 125 TMF 70-700 3p F F UL/CSA
Parameter
Value
Environmental Information
9AKK108467A6707
Product Net Width
90 mm
Product Net Height
130 mm
Product Net Depth / Length
82.5 mm
Product Net Weight
1.1 kg
Circuit Breaker Type to be Associated
Power Distribution
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Suitable for Product Class
SACE Tmax XT
Version
F
CAD Dimensional Drawing
1SDH002230A1001
Connecting Capacity Main Circuit
Busbar 32.5..100 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour 8000 cycle
Mechanical Durability
240 cycles per hour 25000 cycle
Number of Poles
3
Opening Time
CB with SOR 15 ms CB with UVR 15 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 4.4 W
Rated Current (In)
70 A
Rated Instantaneous Short-Circuit Current Setting (Ii)
700 A
Rated Operational Voltage
600 V AC 500 V DC
Rated Uninterrupted Current (Iu)
125 A
Rated Voltage (Ur)
Product Highlights
1. Certified Safety Standards
Description: The XT2H 125 TMF 70-700 3P F F UL/CSA is certified to both UL and CSA standards, ensuring it meets rigorous safety requirements for electrical distribution. This certification guarantees the product's compliance with safety regulations, providing peace of mind for users.
2. Reliable Performance
Description: Designed for reliable performance, the XT2H 125 TMF 70-700 3P F F UL/CSA moulded case circuit breaker is engineered to handle demanding electrical applications. Its robust construction ensures consistent operation under various conditions.
3. Thermomagnetic Release
Description: Equipped with a thermomagnetic release mechanism, the XT2H 125 TMF 70-700 3P F F UL/CSA circuit breaker automatically trips in case of an overload or short circuit, protecting the electrical system and preventing potential damage.
4. Front Terminal Design
Description: The front terminal design of the XT2H 125 TMF 70-700 3P F F UL/CSA makes it easy to install and maintain. This configuration allows for straightforward connections, reducing installation time and enhancing overall efficiency.
5. Compact Dimensions
Description: With dimensions of 8.19 inches in width, 5.71 inches in height, and 5.12 inches in depth, the XT2H 125 TMF 70-700 3P F F UL/CSA is compact and space-efficient, making it ideal for a variety of electrical distribution applications where space is limited.
600 V
Recommended Screw Driver
Main Circuit M6
Release
TMF
Release Type
TM
Setting Range
70 A
Short-Circuit Performance Level
H
Standards
UL489
Sub-type
XT2
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Interrupting Rating acc. to UL489
(240 V AC) 150 kA (480 V AC) 65 kA (600 V AC) 25 kA (250 V DC) 2 Poles in Series 65 kA (500 V DC) 3 Poles in Series 65 kA
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4927 >> Molded case circuit breakers
Object Classification Code
Q
UNSPSC
39121616
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Manufacturer ID
1SDA074797R1
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.
Need Help Checking This Part?
Ask about specifications, condition or a suitable alternative.