ABB NX40E-36: 4-pole contactor relay for auxiliary circuits, 220V/60Hz and 190V/50Hz operation, robust design for industrial use.
Product ModelNX40E-36
Material Number1SBH901074R3640
Product ID74476
Stock on Request
Last updated: 8/29/2026
Key Features
1
1. Reliable OperationThe ABB NX40E-36 contactor relay is designed to provide reliable operation in a wide range of industrial applications. Its robust construction ensures consistent performance, even in demanding environments.
2
2. Versatile Voltage CompatibilityThis contactor relay operates at 220V/60Hz and 190V/50Hz, making it compatible with various electrical systems. This versatility makes it an ideal choice for diverse industrial settings.
3
3. High Switching FrequencyWith a maximum electrical switching frequency of AC-15 1200 cycles per hour, the NX40E-36 can handle high-frequency switching requirements, ensuring efficient control over electrical circuits.
4
4. Mechanically Linked Auxiliary ContactsThe contactor relay features mechanically linked auxiliary contact elements, which provide precise control and reliable switching of auxiliary circuits. This design ensures that the contacts operate in sync, maintaining the integrity of the electrical system.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Product Net Width
44 mm
Product Net Depth / Length
74 mm
Product Net Height
74 mm
Product Net Weight
0.315 kg
Number of Auxiliary Contacts NO
4
Number of Auxiliary Contacts NC
0
5
5. Compliance with International StandardsThe ABB NX40E-36 contactor relay complies with IEC 60947-5-1 and VDE 0110 (Gr. C) 690 volt standards, ensuring that it meets the highest safety and performance standards for electrical equipment. This compliance provides peace of mind for users in terms of safety and reliability.
(500 V) NC 2 (500 V) 2 A (690 V) 2 A (24 / 127 V) 6 A (220 / 240 V) 4 A (380 / 400 V) 3 A (400 / 440 V) 2 A
Rated Short-time Withstand Current Low Voltage (Icw)
for 0.1 s 140 A for 1 s 100 A
Maximum Electrical Switching Frequency
(AC-15) 1200 cycles per hour (DC-13) 900 cycles per hour
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W (110 V) 0.55 A / 60 W (125 V) 0.55 A / 69 W (220 V) 0.30 A / 66 W (250 V) 0.30 A / 75 W (400 V) 2.8 A / 134 W (500 V) 1 A / 72 W
Rated Insulation Voltage (Ui)
acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp)
Auxiliary Circuit 6 kV
Maximum Mechanical Switching Frequency
6000 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 190 V 60 Hz 220 V
Operate Time
Between Coil De-energization and NC Contact Closing 9 ... 16 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms Between Coil Energization and NC Contact Opening 7 ... 21 ms Between Coil Energization and NO Contact Closing 10 ... 26 ms
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
Terminal Type
Screw Terminals
Tightening Torque UL/CSA
Auxiliary Circuit 9 in·lb Control Circuit 9 in·lb
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C Close to Contactor without Thermal O/L Relay -40 ... 70 °C Close to Contactor for Storage -60 ... +80 °C Near Contactor for Operation in Free Air -40 ... 70 °C
Climatic Withstand
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible
Without Derating 3000 m
Object Classification Code
K
ETIM 7
EC000196 - Contactor relay
ETIM 8
EC000196 - Contactor relay
ETIM 9
EC000196 - Contactor relay
eClass
V11.0 : 27371001
UNSPSC
39121500
IDEA Granular Category Code (IGCC)
4755 >> Contactors
Manufacturer ID
1SBH901074R3640