Short Description: The SACE Tmax XT1N 160 TMD 40-450 4P F F is a high-performance, four-pole circuit breaker with a thermomagnetic release, designed for reliable short-circuit protection in various electrical applications.
Specifications for XT1N160 TMD40/450 FFC 4P+RC Inst
Parameter
Value
Environmental Information
9AKK108467A6707
Product Net Width
101.6 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
2.7 kg
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
Current Type
AC
Electrical Durability
8000 cycle 120 cycles per hour
Mechanical Durability
25000 cycle 240 cycles per hour
Number of Poles
4P
Power Loss
at Rated Operating Conditions per Pole 2.6 W
Rated Current (In)
40 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 50 kA (230 V AC) 50 kA (240 V AC) 50 kA (380 V AC) 36 kA (415 V AC) 36 kA (440 V AC) 18 kA (500 V AC) 15 kA (525 V AC) 11 kA (690 V AC) 5 kA
(220 V AC) 65 kA (230 V AC) 65 kA (240 V AC) 65 kA (380 V AC) 36 kA (415 V AC) 36 kA (440 V AC) 36 kA (500 V AC) 30 kA (525 V AC) 22 kA (690 V AC) 6 kA
Rated Uninterrupted Current (Iu)
160 A
Release
TMD
Product Highlights
1. High Short-Circuit Breaking Capacity
The XT1N 160 TMD 40-450 4P F F boasts a high short-circuit breaking capacity, ensuring reliable protection against electrical surges. It can handle up to 65 kA at 220/230 V AC and 36 kA at 380/415/440 V AC.
2. Thermomagnetic Release
Equipped with a thermomagnetic release (TMD), this circuit breaker provides efficient and reliable operation. The TMD ensures that the breaker trips quickly and accurately in case of an overload or short circuit.
3. Four-Pole Configuration
Designed as a four-pole circuit breaker, the XT1N 160 TMD 40-450 4P F F offers comprehensive protection for your electrical system. This configuration ensures that all phases are protected simultaneously, enhancing overall system reliability.
4. Wide Operating Range
The circuit breaker is rated for 40-450 A, making it suitable for a wide range of applications. Its ability to handle various current ranges ensures flexibility and adaptability in different electrical setups.
5. Compliance with International Standards
The XT1N 160 TMD 40-450 4P F F is designed to meet international standards, including IEC, ensuring that it meets the highest safety and performance requirements. This compliance provides peace of mind for users in diverse global applications.
Release Type
TM
Remarks
ATLAS
Short-Circuit Performance Level
N
Standards
IEC60947-2 GB/T 14028.2
Sub-type
XT1
Terminal Connection Type
Front for Copper Cables
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Manufacturer ID
2TFH100492R1001
Specifications may change. Confirm the exact model, revision and offered condition with your quotation.
Need Help Checking This Part?
Ask about specifications, condition or a suitable alternative.