The ABB XT1H 160 TMD 160-1600 4P FF is a high-performance, three-pole circuit breaker designed for reliable power distribution. It features a thermomagnetic release and front terminals, providing safe and precise operation. Suitable for applications needing robust short-circuit breaking capacity.
Specifications for XT1H160 TMD160/1600 FFC 4P N=100%
Parameter
Value
Environmental Information
9AKK108467A6707
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Version
F
Current Type
AC/DC
Electrical Durability
8000 cycle 120 cycles per hour
Mechanical Durability
25000 cycle 240 cycles per hour
Number of Poles
4P
Power Loss
at Rated Operating Conditions per Pole 15 W
Rated Current (In)
160 A
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 75 kA (230 V AC) 75 kA (240 V AC) 75 kA (380 V AC) 52.5 kA (415 V AC) 37.5 kA (440 V AC) 32.5 kA (500 V AC) 25 kA (525 V AC) 17.5 kA (690 V AC) 5 kA (250 V DC) 2 Poles in Series 52.5 kA (500 V DC) 3 Poles in Series 52.5 kA
(220 V AC) 100 kA (230 V AC) 100 kA (240 V AC) 100 kA (380 V AC) 70 kA (415 V AC) 70 kA (440 V AC) 65 kA (500 V AC) 50 kA (525 V AC) 35 kA (690 V AC) 10 kA (250 V DC) 2 Poles in Series 70 kA (500 V DC) 3 Poles in Series 70 kA
Rated Uninterrupted Current (Iu)
160 A
Release
TMD
Release Type
TM
Short-Circuit Performance Level
H
Standards
IEC60947-2 GB/T 14028.2
Product Highlights
1. High Reliability and Efficiency
The XT1H 160 TMD 160-1600 4P FF is engineered to provide consistent performance, ensuring reliable power distribution in various applications.
2. Thermomagnetic Release
Equipped with a thermomagnetic release, this circuit breaker automatically trips in case of an overload or short circuit, ensuring safety and preventing damage.
3. Front Terminal Connection
The front terminal connection makes it easy to install and maintain, reducing downtime and increasing operational efficiency.
4. Robust Short-Circuit Breaking Capacity
Designed to handle high short-circuit currents, this circuit breaker offers a robust breaking capacity, making it suitable for demanding applications.
5. Compliance with International Standards
The XT1H 160 TMD 160-1600 4P FF complies with IEC standards, ensuring it meets the highest safety and performance requirements in the industry.
Sub-type
XT1
Terminal Connection Type
Front for Copper Cables
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
Manufacturer ID
2TFH100188R1001