The ABB B6-22-00-P80 Mini Contactor is a compact, reliable 4-pole contactor with soldering pins, designed for 220-240 VAC, 2 NO + 2 NC configuration, and 60 Hz frequency.
Product ModelB6-22-00-P-80
Material NumberGJL1211509R8000
Product ID69955
Stock on Request
Last updated: 8/29/2026
Key Features
1
1. Compact DesignThe ABB B6-22-00-P80 Mini Contactor is designed to be compact, making it ideal for applications where space is at a premium. Its small footprint ensures it can be easily integrated into various systems without taking up too much room.
2
2. Reliable PerformanceThis contactor is built with reliability in mind. It features a silent coil operation, low coil consumption (3.5 VA at pull-in and at holding), and is designed to handle high operational cycles (up to 10 million cycles).
3
3. Versatile ConfigurationThe contactor comes with a 2 NO + 2 NC configuration, making it versatile for a wide range of applications. This configuration allows for both normally open and normally closed contacts, enhancing its functionality.
4
4. Easy InstallationThe ABB B6-22-00-P80 Mini Contactor is designed for easy installation. It features screw terminals and soldering pins, making it straightforward to connect and integrate into existing systems.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Product Net Width
47.5 mm
Product Net Height
45.2 mm
Product Net Depth / Length
47.7 mm
Product Net Weight
0.17 kg
Number of Poles
4
Mini Contactor Type
Mini Contactor
5
5. High Operating EfficiencyThis contactor is optimized for high operating efficiency. It operates at 220-240 VAC, 60 Hz frequency, and can handle loads up to 20 A at 380/440 V, making it suitable for a variety of industrial and commercial applications.
Rated Operational Voltage
Main Circuit 690 V AC Main Circuit 220 V DC
Rated Frequency (f)
Control Circuit 400 Hz Control Circuit 50 Hz Control Circuit 60 Hz Main Circuit 60 Hz Main Circuit 50 Hz Main Circuit DC
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 6 kV
Rated Insulation Voltage (Ui)
690 V acc. to UL/CSA 600 V
Number of Main Contacts NC
2
Number of Main Contacts NO
2
Rated Operational Current AC-1 (Ie)
(220 / 240 V) 40 °C 12 A (220 / 240 V) 55 °C 12 A (380 / 440 V) 40 °C 12 A (380 / 440 V) 55 °C 12 A (690 V) 40 °C 6 A (690 V) 55 °C 6 A
Rated Operational Power AC-3 (Pe)
(230 V) Three Phase 2.2 kW (400 V) Three Phase 4 kW (500 V) Three Phase 4 kW (690 V) Three Phase, NC 3 kW (690 V) Three Phase, NO 3 kW
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 64 A
Number of Auxiliary Contacts NC
0
Number of Auxiliary Contacts NO
0
Conventional Free-air Thermal Current (Ith)
Main Circuit 12 A
Rated Control Circuit Voltage (Uc)
220 ... 240 V AC
Coil Operating Limits
(acc. to IEC 60947-4-1) for AC supply 0.85 ... 1.1 x Uc (at θ ⤠55 °C)
Degree of Protection
Control Circuit Terminals IP20 Main Circuit Terminals IP20
Mechanical Durability
10000000 cycle
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour (AC-3) 600 cycles per hour (DC-1) 600 cycles per hour (DC-3) 600 cycles per hour
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Power Loss
at Rated Operating Conditions AC-1 per Pole 1 W
Standards
IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1 IEC 60335-2-40 A2L
Maximum Operating Voltage UL/CSA
Main Circuit 600 V AC
Full Load Amps Motor Use
(115 V AC) Single Phase 5.8 A (200 V AC) Three Phase 4.8 A (220 ... 240 V AC) Three Phase 6.8 A (230 V AC) Single Phase 4.9 A (440 ... 480 V AC) Three Phase 4.8 A (550 ... 600 V AC) Three Phase 1.7 A
Horsepower Rating UL/CSA
(115 V AC) Single Phase 0.25 Hp (200 V AC) Three Phase 1 Hp (220 ... 240 V AC) Three Phase 2 Hp (230 V AC) Single Phase 0.5 Hp (440 ... 480 V AC) Three Phase 3 Hp (550 ... 600 V AC) Three Phase 1 Hp