The ABB F204 B S-63/0.5 Residual Current Circuit Breaker offers advanced protection against fault currents to earth, ensuring safety and reliability in your installations.
Product ModelF204 B S-63/0.5
Material Number2CSF204892R4630
Product ID69531
Stock on Request
Last updated: 8/29/2026
Key Features
1
Feature1. Advanced Protection Against Fault Currents The F204 B S-63/0.5 provides robust protection against fault currents to earth, safeguarding people and installations from potential hazards.
2
Feature2. Selective and Instantaneous Protection This RCCB offers both selective and instantaneous protection, ensuring that only the faulty circuit is interrupted, minimizing downtime and reducing the risk of damage.
3
Feature3. High Reliability and Durability Built with high-quality components, the F204 B S-63/0.5 is designed to provide reliable operation over extended periods, ensuring continuous protection.
4
Feature4. Easy Installation and Maintenance The product features a user-friendly design, making installation and maintenance straightforward. Its compact size also facilitates easier integration into existing systems.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Standards
IEC/EN 61008-1, IEC/EN 61008-2-1, EN 62423
Type of Residual Current
Type B
Rated Voltage (Ur)
230/400 V
Rated Operational Voltage
230 ⦠400 V AC
Rated Insulation Voltage (Ui)
500 V
Test Voltage (Ut)
110 ... 253 V
5
Feature5. Compliance with International Standards The F204 B S-63/0.5 complies with international standards for RCCBs, ensuring it meets the highest safety and performance requirements in various applications.
Rated Impulse Withstand Voltage (Uimp)
4 kV
Dielectric Test Voltage
2500 V
Input Voltage Type
AC
Rated Current (In)
63 A
Rated Residual Current
500 mA
Rated Conditional Short-Circuit Current (Inc)
(Typ gG/gLfuse, 500 V) 100 A Selective MCB S750-E 63A or S750DR-E/K 100 A
Maximum Surge Current
5 kA
Leakage Current Type
B
Frequency (f)
50/60 Hz
Rated Frequency (f)
50 ⦠60 Hz
Power Loss
Total 17.9 W
Power Supply Connection
Arbitrary
Electrical Endurance
10000 cycle
Number of Poles
4
Number of Modular Spacings per DIN Rail
4
Operating Characteristic
Selective
Position of Neutral Terminals
Right
Tightening Torque
2.8 N·m
Accessory Type