WAGO 750-364/040-010 Fieldbus Coupler for Modbus TCP M12, 4th gen, extreme conditions. Ideal for industrial automation.
Product Model750-364/040-010
Product ID49128
Stock on Request
Last updated: 8/29/2026
Key Features
1
FeatureAdvanced 4th Generation Technology
2
FeatureModbus TCP M12 Connectivity
3
FeatureDesigned for Extreme Conditions
4
FeatureIdeal for Industrial Automation and Networking
5
FeatureHigh Reliability and Performance
6
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
Specifications may be subject to change without notice
Parameter
Value
Parameter
Value
Communications
Modbus (TCP, UDP)
ETHERNET protocols
HTTP(S)
Transmission rate
10/100 Mbit/s
Transmission medium (communication/fieldbus)
Twisted pair S-UTP; 100 Ω; Cat. 5; M12 D-coded; 100 m maximum cable length
Transmission performance
Class D per EN 50173
Number of modules per node (max.)
64
FeatureAdvanced 4th Generation Technology
7
FeatureModbus TCP M12 Connectivity
8
FeatureDesigned for Extreme Conditions
9
FeatureIdeal for Industrial Automation and Networking
10
FeatureHigh Reliability and Performance
Number of modules without a bus extension (max.)
64
Configuration options
WAGO-I/O-CHECK
Input and output process image (fieldbus) max.
1020 words/1020 words
Supply voltage (system)
24 VDC; via pluggable connector (CAGE CLAMP® connection); Derating must be observed!
Current consumption (5 V system supply)
350mA
Total current (system supply)
1,700mA
Supply voltage (field)
24 VDC; Power supply via pluggable connector (CAGE CLAMP® connection); Transmission via power jumper contacts; Derating must be observed!
Input current (typ.) at nominal load (24 V)
500mA
Power supply efficiency (typ.) at nominal load (24 V)
90%
Current carrying capacity (power jumper contacts)
10A
Rated surge voltage
1 kV
Derating
Derating (supply voltage):Ambient temperatures under laboratory conditions: (?25 +30°%);for ?40 +55掳°C: 24掳V (?25 +20°%);for +55 +70°°C: 24掳V (?25 +10°%);Lower limit in all temperature ranges: ?27.5°% (including 15°% residual ripple)
Indicators
LED (LINK/ACT) green: Network connection via ports 1 2; LED (MS, NS) red/green: Status of node, network; LED (I/O) red/green/orange: Status of local data bus
Connection technology: communication/fieldbus
Modbus (TCP, UDP): 2 x M12 socket; 4-pole; D-coded
Connection technology: field supply
6 x CAGE CLAMP®
Connection technology: system supply
2 x CAGE CLAMP®
Connection type 1
System/field supply
Solid conductor
0.25 2.5 mm2 / 24 14 AWG
Fine-stranded conductor
0.25 2.5 mm2 / 24 14 AWG
Strip length
8 9 mm / 0.31 0.35 inches
Connection technology: device configuration
1 x Male connector; 4-pole
Width
112 mm / 4.409 inches
Height
100 mm / 3.937 inches
Depth
71.9 mm / 2.831 inches
Depth from upper-edge of DIN-rail
64.7 mm / 2.547 inches
Mounting type
DIN-35 rail
Housing material
Polycarbonate; polyamide 6.6
Fire load
3.284MJ
Weight
213g
Conformity marking
CE
Ambient temperature (operation)
-40 … +70 °C
Ambient temperature (storage)
-40 … 85 °C
Protection type
IP20
Pollution degree
2 per IEC 61131-2
Operating altitude
without temperature derating: 0 2000 m; with temperature derating: 2000 5000 m (0.5 K/100 m); 5000 m (max.)
Mounting position
Horizontal left, horizontal up, vertical top and vertical bottom
Relative humidity (without condensation)
95%
Relative humidity (with condensation)
Short-term condensation per Class 3K7/IEC EN 60721-3-3 and E-DIN 40046-721-3 (except for wind-driven precipitation, water and ice formation)
Vibration resistance
per IEC 60068-2-6 (acceleration: 5g), EN 60870-2-2, IEC 60721-3-1, -3, EN 50155; EN 61373
Shock resistance
per IEC 60068-2-27 (15g/11 ms/half-sine/1,000 shocks; 25g/6 ms/1,000 shocks), EN 50155, EN 61373
EMC immunity to interference
per EN 61000-6-1, -2; EN 61131-2; marine applications; EN 50121-3-2; EN 50121-4, -5; EN 60255-26;EN 60870-2-1; EN 61850-3; IEC 61000-6-5; IEEE 1613; VDEW: 1994
EMC emission of interference
per EN 61000-6-3, -4, EN 61131-2, EN 60255-26, marine applications, EN 60870-2-1, EN 61850-3, EN 50121-3-2, EN 50121-4, -5
Exposure to pollutants
per IEC 60068-2-42 and IEC 60068-2-43
Permissible pollutant concentration H2S at a relative humidity < 75%
10ppm
Permissible pollutant concentration SO 2 at a relative humidity < 75%